INSTALLATION<br />

32<br />

35 REPLACING PRE-FITTED MAINS CABLE<br />

If it is necessary to use an alternative mains cable to the one<br />

pre-fitted then use the following guide.<br />

Replacement wiring should comply with notes in Frame 33.<br />

1. Isolate the mains supply to the boiler.<br />

2. Remove the front panel. Refer to Frame 45.<br />

3. Swing the control box down into the service position.<br />

Refer to Frame 46.<br />

4. Remove the terminal block cover to access the terminals<br />

for electrical connections.<br />

5. Remove the mains cover to access the earth post.<br />

6. Remove the live and neutral wires from the terminal block.<br />

7. Remove the top nut from the earth post and remove the<br />

earth connection ring terminal from the post.<br />

8. Slacken the cable gland and withdraw the mains cable.<br />

esp8931<br />

4<br />

INSTALLATION<br />

5<br />

9. Route replacement cable back through the cable gland<br />

and re-tighten to provide cord anchorage.<br />

10. Connect the earth wire to the earth post by trapping the<br />

stripped end between the cupped and flat washer. Secure<br />

with nut provided.<br />

11. Connect the live and neutral wires to the terminal strip.<br />

When making the mains electrical connections to the<br />

boiler it is important that the wires are prepared in such a<br />

way that the earth conductor is longer than the current<br />

carrying conductors, such that if the cord anchorage<br />

should slip, the current carrying conductors become taut<br />

before the earthing conductor.<br />

12. Re-fit the mains and terminal block covers ensuring<br />

cables are located in the cable entry position.<br />

13. Swing the control box back up into the operating position<br />

and re-fit the front panel ensuring a good seal is made.<br />

Earth Post<br />