<strong>DELTA</strong> style<br />
© Siemens AG <strong>2011</strong><br />
Shutter/blind controls<br />
Ve<strong>rs</strong>ion DT Order No. Price<br />
per PU<br />
PU<br />
(UNIT,<br />
S<strong>ET</strong>,<br />
M)<br />
PS*/<br />
P. unit<br />
PG<br />
6<br />
5TC1 560<br />
5TC1 270<br />
5TC1 271<br />
Comfort shutter/blind controls<br />
• For controlling a blind or shutter motor with mechanical or electronic<br />
limit switches <strong>and</strong> comprehensive functionality (see product features)<br />
• Menu-controlled operation by means of 4 control buttons<br />
Ve<strong>rs</strong>ions<br />
• Titanium white (similar to RAL 9010) A 5TC1 560 1 1 unit 024<br />
• Platinum metallic (similar to RAL 9007) A 5TC1 560-1 1 1 unit 024<br />
• Basalt black (similar to RAL 7016)<br />
On request<br />
Note Section Page<br />
The sun sensor must be ordered<br />
separately, see ...<br />
Product features<br />
Accessories <strong>and</strong> spare<br />
parts<br />
• Flush-mounting device without an extension unit input<br />
• 230 V AC, 50 Hz (N conductor required)<br />
• For screw <strong>and</strong> claw fixing<br />
• Type of connection: screw terminals<br />
• 2 relays which are electrically interlocked against each other with a<br />
minimum switchover time of approx. 1 s<br />
• Bridging of voltage interruptions < 0.2 s<br />
• Connected load: max. 1 motor up to 1000 W<br />
• Pulse duration: 2 min factory setting, may be changed to as much as<br />
12 min by programming<br />
• Accuracy: ± 1 min per month<br />
• Reserve power: approx. 24 h<br />
• Switching times: max. 18 (can be split up in three memories)<br />
• Factory preset switching times for faster commissioning<br />
• Possible reset to factory settings<br />
• R<strong>and</strong>om generator ± 15 min<br />
• Astro program (can be delayed by ± 1 h 59 min)<br />
• Easy changeover to daylight savings<br />
• Twilight <strong>and</strong> sun protection function is possible with an optional sun<br />
sensor<br />
• The r<strong>and</strong>om <strong>and</strong> astro functions can be combined<br />
• Manual operation possible at any time<br />
6/37 A 5TC1 526 1 1 unit 024<br />
Shutter/blind control flush-mounting isolating relays<br />
• Double, with individual control<br />
• Relay for the control of several shutte<strong>rs</strong> or blinds<br />
• Two moto<strong>rs</strong> can be controlled per isolating relay, even if further isolating<br />
relays are connected downstream<br />
• Option for individual control of connected moto<strong>rs</strong> over shutter/blind<br />
pushbutton (e.g. 5TA2 114)<br />
• The isolating relay is to be installed into a surface-mounting or flushmounting<br />
box (flush-mounting box from 70 mm ∅ or surface-mounting<br />
boxes from 100 mm x 100 mm)<br />
• Only for in-phase operation<br />
• 8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz<br />
• 58 mm x 59 mm x 22 mm<br />
A 5TC1 270 1 1 unit 024<br />
Note Section Page<br />
For Technical specifications, see ... Technical Information /<br />
Shutter/Blind Controls /<br />
Shutter/blind control<br />
flush-mounting isolating<br />
relays<br />
Shutter/blind control flush-mounting isolating relays, compact<br />
• Relay for the control of several shutte<strong>rs</strong> or blinds<br />
• A maximum of two moto<strong>rs</strong> can be connected per compact isolating relay,<br />
whereby the drive connected to the marked motor terminals can<br />
also be individually controlled over a shutter/blind pushbutton<br />
• If cascaded, a motor can be connected to each compact isolating relay,<br />
which can also be individually controlled over a shutter/blind pushbutton<br />
• The isolating relay is to be installed into a surface-mounting or flushmounting<br />
box (flush-mounting box from 60 mm ∅, 40 mm deep or surface-mounting<br />
boxes from 75 mm x 75 mm)<br />
• Only for in-phase operation<br />
• 8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz<br />
• 50 mm x 53 mm x 22 mm<br />
A 5TC1 271 1 1 unit 024<br />
19/58<br />
Note Section Page<br />
For Technical specifications, see ... Technical Information /<br />
Shutter/Blind Controls /<br />
Shutter/blind control<br />
flush-mounting isolating<br />
relays, compact<br />
19/59<br />
6/18 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />
* You can order this quantity or a multiple thereof.