<strong>DELTA</strong> style<br />

© Siemens AG <strong>2011</strong><br />

Shutter/blind controls<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

6<br />

5TC1 560<br />

5TC1 270<br />

5TC1 271<br />

Comfort shutter/blind controls<br />

• For controlling a blind or shutter motor with mechanical or electronic<br />

limit switches <strong>and</strong> comprehensive functionality (see product features)<br />

• Menu-controlled operation by means of 4 control buttons<br />

Ve<strong>rs</strong>ions<br />

• Titanium white (similar to RAL 9010) A 5TC1 560 1 1 unit 024<br />

• Platinum metallic (similar to RAL 9007) A 5TC1 560-1 1 1 unit 024<br />

• Basalt black (similar to RAL 7016)<br />

On request<br />

Note Section Page<br />

The sun sensor must be ordered<br />

separately, see ...<br />

Product features<br />

Accessories <strong>and</strong> spare<br />

parts<br />

• Flush-mounting device without an extension unit input<br />

• 230 V AC, 50 Hz (N conductor required)<br />

• For screw <strong>and</strong> claw fixing<br />

• Type of connection: screw terminals<br />

• 2 relays which are electrically interlocked against each other with a<br />

minimum switchover time of approx. 1 s<br />

• Bridging of voltage interruptions < 0.2 s<br />

• Connected load: max. 1 motor up to 1000 W<br />

• Pulse duration: 2 min factory setting, may be changed to as much as<br />

12 min by programming<br />

• Accuracy: ± 1 min per month<br />

• Reserve power: approx. 24 h<br />

• Switching times: max. 18 (can be split up in three memories)<br />

• Factory preset switching times for faster commissioning<br />

• Possible reset to factory settings<br />

• R<strong>and</strong>om generator ± 15 min<br />

• Astro program (can be delayed by ± 1 h 59 min)<br />

• Easy changeover to daylight savings<br />

• Twilight <strong>and</strong> sun protection function is possible with an optional sun<br />

sensor<br />

• The r<strong>and</strong>om <strong>and</strong> astro functions can be combined<br />

• Manual operation possible at any time<br />

6/37 A 5TC1 526 1 1 unit 024<br />

Shutter/blind control flush-mounting isolating relays<br />

• Double, with individual control<br />

• Relay for the control of several shutte<strong>rs</strong> or blinds<br />

• Two moto<strong>rs</strong> can be controlled per isolating relay, even if further isolating<br />

relays are connected downstream<br />

• Option for individual control of connected moto<strong>rs</strong> over shutter/blind<br />

pushbutton (e.g. 5TA2 114)<br />

• The isolating relay is to be installed into a surface-mounting or flushmounting<br />

box (flush-mounting box from 70 mm ∅ or surface-mounting<br />

boxes from 100 mm x 100 mm)<br />

• Only for in-phase operation<br />

• 8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz<br />

• 58 mm x 59 mm x 22 mm<br />

A 5TC1 270 1 1 unit 024<br />

Note Section Page<br />

For Technical specifications, see ... Technical Information /<br />

Shutter/Blind Controls /<br />

Shutter/blind control<br />

flush-mounting isolating<br />

relays<br />

Shutter/blind control flush-mounting isolating relays, compact<br />

• Relay for the control of several shutte<strong>rs</strong> or blinds<br />

• A maximum of two moto<strong>rs</strong> can be connected per compact isolating relay,<br />

whereby the drive connected to the marked motor terminals can<br />

also be individually controlled over a shutter/blind pushbutton<br />

• If cascaded, a motor can be connected to each compact isolating relay,<br />

which can also be individually controlled over a shutter/blind pushbutton<br />

• The isolating relay is to be installed into a surface-mounting or flushmounting<br />

box (flush-mounting box from 60 mm ∅, 40 mm deep or surface-mounting<br />

boxes from 75 mm x 75 mm)<br />

• Only for in-phase operation<br />

• 8 A (AC-1) or 3 A (ind.), 230 V AC, 50 Hz<br />

• 50 mm x 53 mm x 22 mm<br />

A 5TC1 271 1 1 unit 024<br />

19/58<br />

Note Section Page<br />

For Technical specifications, see ... Technical Information /<br />

Shutter/Blind Controls /<br />

Shutter/blind control<br />

flush-mounting isolating<br />

relays, compact<br />

19/59<br />

6/18 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

* You can order this quantity or a multiple thereof.