DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Room Temperature Controlle<strong>rs</strong><br />
© Siemens AG <strong>2011</strong><br />
Inserts<br />
■ Selection <strong>and</strong> ordering data<br />
Ve<strong>rs</strong>ion DT Order No. Price<br />
per PU<br />
PU<br />
(UNIT,<br />
S<strong>ET</strong>,<br />
M)<br />
PS*/<br />
P. unit<br />
PG<br />
14<br />
5TC9 200<br />
5TC9 201<br />
5TC9 202<br />
General information<br />
•For screw fixing<br />
• With screwless terminals<br />
Room temperature controlle<strong>rs</strong>, 1 NC contact<br />
• 1/N 230 V/240 V AC, 50 Hz, 10 A (4 A)<br />
• St<strong>and</strong>ard ve<strong>rs</strong>ion with nighttime reduction<br />
• For electric <strong>and</strong> warm water convecto<strong>rs</strong>, pumps <strong>and</strong> tank control<br />
• The temperature controller operates as two-position controller with thermal<br />
feedback<br />
• If the temperature on the bimetal increases <strong>and</strong> the setpoint value is<br />
reached, the NC contact (heating contact) switches off<br />
• If the temperature on the bimetal sinks below the setpoint value minus the<br />
hysteresis, the NC contact switches back on<br />
• Activation of the temperature reduction lowe<strong>rs</strong> the temperature range by<br />
approx. 5 K<br />
For tops see section<br />
Page (ff.)<br />
• Design / i-system / Room Temperature Controlle<strong>rs</strong> 1/31<br />
• Design / <strong>DELTA</strong> profil / Room Temperature Controlle<strong>rs</strong> 5/28<br />
• Design / <strong>DELTA</strong> style / Room Temperature Controlle<strong>rs</strong> 6/23<br />
Note Section Page<br />
For Technical specifications, see ... Technical Information / Room<br />
Temperature Controlle<strong>rs</strong> /<br />
Room temperature controlle<strong>rs</strong>,<br />
with 1 NC contact<br />
19/60<br />
Room temperature controlle<strong>rs</strong>, 1 CO contact<br />
• 1/N 230 V/240 V AC, 50 Hz, 10 A (4 A)<br />
• Normal ve<strong>rs</strong>ion<br />
• For electric <strong>and</strong> warm water convecto<strong>rs</strong>, pumps <strong>and</strong> tank control<br />
• The temperature controller operates as two-position controller with thermal<br />
feedback<br />
• If the temperature on the bimetal increases <strong>and</strong> the setpoint value is<br />
reached, the NC contact (heating contact) switches off <strong>and</strong> the NO contact<br />
(cooling contact) closes<br />
• If the temperature on the bimetal sinks below the setpoint value minus the<br />
hysteresis, the NC contact switches back on<br />
For tops see section<br />
Page (ff.)<br />
• Design / i-system / Room Temperature Controlle<strong>rs</strong> 1/31<br />
• Design / <strong>DELTA</strong> profil / Room Temperature Controlle<strong>rs</strong> 5/28<br />
• Design / <strong>DELTA</strong> style / Room Temperature Controlle<strong>rs</strong> 6/23<br />
Note Section Page<br />
For Technical specifications, see ... Technical Information / Room<br />
Temperature Controlle<strong>rs</strong> /<br />
Room temperature controlle<strong>rs</strong>,<br />
with 1 CO contact<br />
19/60<br />
A 5TC9 200 1 1 unit 024<br />
A 5TC9 201 1 1/100 units 024<br />
Room temperature controlle<strong>rs</strong>, 3-position switch<br />
• 1/N 230 V/240 V AC, 50 Hz, 10 A (4 A)<br />
• With 3-position switches: automatic timing, constant day temperature, constant<br />
nighttime reduction<br />
• For electric <strong>and</strong> warm water convecto<strong>rs</strong>, pumps <strong>and</strong> tank control<br />
• The S1 switch can be used to preselect between time/day <strong>and</strong> night to control<br />
temperature reduction<br />
• The temperature controller operates as two-position controller with thermal<br />
feedback<br />
• If the temperature on the bimetal increases <strong>and</strong> the setpoint value is<br />
reached, the NC contact (heating contact) switches off<br />
• If the temperature on the bimetal sinks below the setpoint value minus the<br />
hysteresis, the NC contact switches back on<br />
• Activation of the temperature reduction lowe<strong>rs</strong> the temperature range by<br />
approx. 5 K<br />
A 5TC9 202 1 1 unit 024<br />
For tops see section<br />
Page (ff.)<br />
• Design / i-system / Room Temperature Controlle<strong>rs</strong> 1/31<br />
• Design / <strong>DELTA</strong> profil / Room Temperature Controlle<strong>rs</strong> 5/28<br />
• Design / <strong>DELTA</strong> style / Room Temperature Controlle<strong>rs</strong> 6/23<br />
Note Section Page<br />
For Technical specifications, see ... Technical Information / Room<br />
Temperature Controlle<strong>rs</strong> /<br />
Room temperature controlle<strong>rs</strong>,<br />
3-position switches<br />
19/61<br />
14/2 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />
* You can order this quantity or a multiple thereof.