Technical Information<br />

Room Temperature Controlle<strong>rs</strong><br />

Room temperature controlle<strong>rs</strong>, 1 NC contact<br />

(5TC9 200)<br />

■ Function<br />

© Siemens AG <strong>2011</strong><br />

■ Schematics<br />

+<br />

! <br />

&<br />

<br />

#<br />

! "<br />

1 & # # !<br />

5 A J J E C H = C A J H A H<br />

N<br />

L<br />

N<br />

TA<br />

<<br />

RF<br />

Legend:<br />

L = Outer conductor (phase)<br />

N = Neutral conductor<br />

= Connection for time switch<br />

(or switch) for nighttime/<br />

temperature reduction<br />

= Load connection (heating)<br />

RF= Resistance for thermal<br />

feedback<br />

TA = Resistance for temperature<br />

reduction<br />

Range restriction in the setting button<br />

I2_08554<br />

■ Technical specifications<br />

Temperature range 5 … 30 °C<br />

Operational voltage<br />

230 V AC, 50/60 Hz<br />

Switch contact<br />

1 NC contact<br />

Rated current<br />

10 (4) A<br />

Switching temperature difference Approx. 0.5 K<br />

Temperature reduction<br />

Approx. 4 K<br />

Degree of protection/safety class IP30/totally insulated<br />

Room temperature controlle<strong>rs</strong>, 1 CO contact<br />

(5TC9 201)<br />

■ Function<br />

■ Schematics<br />

+<br />

! <br />

&<br />

<br />

#<br />

! "<br />

1 & # # !<br />

5 A J J E C H = C A J H A H<br />

L<br />

N<br />

L<br />

N<br />

<<br />

RF<br />

Legend:<br />

L = Outer conductor (phase)<br />

N = Neutral conductor<br />

= Load connection (heating)<br />

= Load connection (cooling)<br />

RF= Resistance for thermal<br />

feedback<br />

Range restriction in the setting button<br />

I2_08555<br />

■ Technical specifications<br />

Temperature range 5 … 30 °C<br />

Operational voltage<br />

Switch contact<br />

Rated current<br />

Switching temperature difference<br />

Temperature reduction<br />

Degree of protection/safety class<br />

230 V AC, 50/60 Hz<br />

1 CO contact<br />

10 (4) A (heating)<br />

5 (2) A (cooling)<br />

Approx. 0.5 K<br />

Approx. 4 K<br />

IP30/totally insulated<br />

19<br />