© Siemens AG <strong>2011</strong><br />

Smoke Detecto<strong>rs</strong><br />

Smoke detecto<strong>rs</strong><br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

5TC1 296<br />

<strong>DELTA</strong> reflex SD230N smoke detecto<strong>rs</strong><br />

• 230 V-operated smoke detector incl. 9 V backup battery with<br />

VdS certification (suitable for networking)<br />

• The smoke detector detects smoke from fires <strong>and</strong> gives early warning.<br />

• As well as using the smoke detector on its own, it is also possible to<br />

network up to 38 smoke detecto<strong>rs</strong> of the same type<br />

• Battery change display for 30 days<br />

• Battery compartment check<br />

• Test button for function test<br />

• Titanium white (similar to RAL 9010)<br />

A 5TC1 296 1 1 unit 024<br />

Technical specifications<br />

• Power supply<br />

230 V AC <strong>and</strong> 9 V alkaline backup battery<br />

(included in delivery)<br />

• Networking<br />

Up to 38 smoke detecto<strong>rs</strong> of the same<br />

type<br />

• Signaling<br />

Acoustic signal transducer:<br />

horn > 85 dB(A)<br />

Optical indicator: red LED<br />

• Temperature range 0 .... +50 °C<br />

• Dimensions (Ø x H) 111 mm x 40 mm<br />

• Mounting<br />

Surface mounting with or without surfacemounting<br />

box (see accessories)<br />

• Degree of protection IP20<br />

•Approvals VdS certification acc. to EN 14604 10/05<br />

Outlet boxes for "<strong>DELTA</strong> reflex SD230N smoke detecto<strong>rs</strong>"<br />

• Surface-mounting box for SD230N smoke detector<br />

• Dimensions: 93 mm x 27 mm<br />

• The outlet box is required if no flush-mounting box to hold the 230 V<br />

connector is provided<br />

• Titanium white (similar to RAL 9010)<br />

A 5TC1 297 1 1 unit 024<br />

5TC1 297<br />

5TC1 291<br />

<strong>DELTA</strong> reflex smoke detector modules "Relais"<br />

• The <strong>DELTA</strong> reflex smoke detector "Batterie" can also be equipped with<br />

a relay module<br />

• The relay module enables the operation of alarm devices such as<br />

horns, sirens, warning lights etc. or connection to the GAMMA instabus<br />

building management systems<br />

• The potential-free changeover contact (NC contact <strong>and</strong> NO contact)<br />

can also be used to set up closed-circuit protection (alarm loops with<br />

NC contact)<br />

• The contacts of the relay are configured through a triple plug-in terminal<br />

• The relay module is powered (3 to 5 V) through the interface of the<br />

smoke detector<br />

A 5TC1 291 1 1 unit 024<br />

Technical specifications<br />

• Operational voltage<br />

• Relay switching voltage<br />

• Relay switching current<br />

• Relay contacts<br />

•Terminals<br />

• Mounting<br />

• Connection<br />

Note<br />

3 ... 5 V<br />

Max. 30 V DC / 42 V AC<br />

Max. 1 A DC / 0.5 A AC<br />

Changeover contact (NC <strong>and</strong> NO contacts)<br />

Max. 0.6 mm Ø<br />

Can only be used in the <strong>DELTA</strong> reflex<br />

smoke detector "Batterie"<br />

Using 8-pole plug connector<br />

The externally connected signaling devices must have their own power<br />

supply.<br />

17<br />