Technical Information<br />

Shutter/Blind Controls<br />

© Siemens AG <strong>2011</strong><br />

sys shutter/blind control inserts (5TC1 231)<br />

■ Schematics<br />

Sample connection<br />

Example 2:<br />

Group control with 2 moto<strong>rs</strong> <strong>and</strong> central operating point<br />

230 V AC ~<br />

PE<br />

N<br />

L<br />

Application options<br />

1<br />

2<br />

3<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

N<br />

5TC1 231<br />

Example 1:<br />

Shutter/blind control with conventional extension units<br />

IN<br />

M<br />

1~<br />

M<br />

L<br />

I2_08611<br />

Neutral conductor<br />

Secondary input UP<br />

Secondary input DOWN<br />

Motor UP<br />

Motor DOWN<br />

External conductor connection<br />

Interface (230-V-PEI)<br />

6<br />

5<br />

4<br />

7<br />

4<br />

5<br />

M<br />

M<br />

AC 230 V ~<br />

PE N L<br />

1<br />

N L<br />

5TC1 231<br />

2<br />

IN M 4<br />

N L<br />

IN M<br />

5TC1 231<br />

N L<br />

IN M<br />

5TC1 231<br />

3<br />

5TA2 114<br />

I2_08613<br />

230 V ~ AC<br />

PE<br />

N<br />

L<br />

L<br />

1 2 M<br />

1~<br />

N<br />

IN M<br />

5TC1 231<br />

When using the shutter/blind pushbutton (5TA2 114), the<br />

shutter/blind can be manually moved to the required position<br />

(UP/DOWN or STEP comm<strong>and</strong>). The number of connectable<br />

conventional extension units is unlimited.<br />

L<br />

I2_08612a<br />

Together with the UP 211 wave shutter/blind pushbutton inserts,<br />

the sys shutter/blind control insert $ is implemented as a central<br />

operating point. The inserts % <strong>and</strong> & individually control the<br />

respective shutter/blind moto<strong>rs</strong> M (( <strong>and</strong> )). The time values<br />

stored in the UP 211 wave shutter/blind pushbutton<br />

(e.g. 8:00 UP <strong>and</strong> 20:00 DOWN comm<strong>and</strong>) allow the timecontrolled<br />

stopping <strong>and</strong> starting of all connected moto<strong>rs</strong>.<br />

Caution:<br />

• It is not permissible to use a shutter/blind control sys insert as<br />

the central operating point <strong>and</strong> directly operate a shutter/blind<br />

motor.<br />

• When protecting the central operating point against short circuit<br />

using a separate residual current operated circuit breaker,<br />

both circuits must be isolated in order to prevent inadvertent<br />

tripping of the circuit breaker.<br />

Example 3:<br />

Integrating a wind alarm<br />

The indicator for the wind alarm is integrated in the shutter/blind<br />

control over the extension unit input. In the event of a wind alarm,<br />

the shutte<strong>rs</strong>/blinds are raised <strong>and</strong> locked in that position until the<br />

wind alarm is reset over the indicator. As long as the interlock is<br />

enabled, neither manual nor automatic operation of the shutte<strong>rs</strong>/<br />

blinds is possible.<br />

19<br />

19/52 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010