© Siemens AG <strong>2011</strong><br />

Technical Information<br />

Motion detecto<strong>rs</strong><br />

Comfort motion detector tops<br />

The 2.20 m lens<br />

<br />

Recommended mounting height<br />

<br />

The lens has three ranges of sensing levels, so that the sensing range is<br />

divided into near, medium <strong>and</strong> distant range.<br />

2,20 m<br />

8°<br />

17°<br />

65°<br />

80°<br />

I2_12398<br />

Level 3<br />

2,30 m<br />

4,30 m<br />

Level 1<br />

Level 2<br />

6,40 m<br />

12,00 m<br />

3,90 m<br />

8,10 m<br />

1 & % '<br />

Mode of operation of the 2.20 m lens<br />

<br />

1 & & <br />

1 & & <br />

Sensing range of the 2.20 m lens<br />

Avoidance of sources of interference<br />

In order to avoid unintended switching operations, the following<br />

instructions should be complied with during installation:<br />

• As a result of the thermal radiation from the lighting or an insufficient<br />

distance between the motion detector <strong>and</strong> the lamp,<br />

an undefined switch-on operation may be initiated.<br />

Use of the plug-on blind<br />

= <br />

= <br />

The sensing levels of the 2.20 m lens arranged from the top to the bottom<br />

The mounting height generally amounts to 2.20 or 1.10 m.<br />

If a mounting height higher than 2.20 m is selected, please note<br />

that under certain circumstances the energy radiated by a more<br />

distant heat signal source is not sufficient to release the motion<br />

detector top.<br />

The lens has a sensing range with an opening angle of 180° in<br />

three levels. The three levels are directed from top to bottom.<br />

The size of the sensing range equals<br />

• For a mounting height of 2.20 m: approx. 12 m x 12 m<br />

• For an mounting height of 1.10 m: approx. 6 m x 6 m<br />

• When selecting the mounting location, it should be ensured<br />

that no sources of interference, e.g. lamps or heate<strong>rs</strong> are positioned<br />

within the sensing field. If this is not possible, a plugon<br />

blind should be used.<br />

(1,10 m)<br />

2<br />

1<br />

(2,20 m)<br />

3<br />

2<br />

1<br />

I2_08793<br />

1<br />

2<br />

3<br />

Sensing range<br />

Suppressed range<br />

Blind<br />

Using the plug-on blind, sources of interference can be suppressed<br />

by narrowing the sensing range. The blind cove<strong>rs</strong> 90°<br />

of the left or right sensing range.<br />

19<br />

Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

19/39