DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Remote Control Systems<br />
GAMMA wave — the Multifunctional Radio System<br />
Inserts<br />
© Siemens AG <strong>2011</strong><br />
16<br />
5TC1 233<br />
5WG3 560-2AB01<br />
5TC1 230<br />
Ve<strong>rs</strong>ion DT Order No. Price €<br />
per PU<br />
sys switching inserts, 15 to 500 VA<br />
• The sys switching insert is a flush-mounting device for switching<br />
different electrical consume<strong>rs</strong>, such as<br />
- Inc<strong>and</strong>escent lamps<br />
- HV halogen lamps<br />
- LV halogen lamps with conventional transformer<br />
- LV halogen lamps with electronic transformer<br />
• It is operated by means of the UP 210 wave pushbutton<br />
For tops see section<br />
Page<br />
• Design / i-system / <strong>Switches</strong> <strong>and</strong> Pushbuttons 1/6<br />
• Design / <strong>DELTA</strong> profil/<strong>Switches</strong> <strong>and</strong> Pushbuttons 5/8<br />
• Design / <strong>DELTA</strong> style/<strong>Switches</strong> <strong>and</strong> Pushbuttons 6/6<br />
Product features<br />
• 2-wire connection method<br />
• Spare fuse at the fuse holder<br />
• Overload protection (thermal release)<br />
• Extension unit operation over conventional pushbuttons without glow<br />
lamps<br />
Technical specifications<br />
• Short-circuit protection by miniature T 3.15 A H 250 V<br />
fuse<br />
• Number of extension units Unlimited<br />
• Extension unit cable (total) Max. 100 m<br />
• Rated voltage<br />
230 V AC/50 Hz<br />
• Connected load<br />
- Inc<strong>and</strong>escent lamp rating 15 ... 500 W<br />
- Conventional transforme<strong>rs</strong> (except 15 ... 500 W<br />
toroidal-core transforme<strong>rs</strong>)<br />
- Toroidal-core transforme<strong>rs</strong> 15 ... 250 W<br />
UP 560 wave wall-mounted transmitter "Aktor" 230 V<br />
• Radio transmitter for the wireless operation of room functions, which is<br />
also equipped with a switch actuator for 230 V / 6 A<br />
• For installation in flush-mounting switch boxes<br />
•An instabus KNX/EIB single or double pushbutton is plugged on as<br />
operator interface <strong>and</strong> connected to the insert by means of a 10-pole<br />
plug-in connection<br />
• The following functions can be parameterized: switching, dimming,<br />
shutter/blind <strong>and</strong> scene<br />
• As an additional function, the switch actuator can be operated as a<br />
timer with an adjustable delay time in the range from 1 ... 60 min<br />
• 6 A rated current for resistive load at 230 V AC<br />
• Modular width 71 mm<br />
• Mounting depth 32 mm<br />
For tops see section<br />
Page<br />
• Design / <strong>DELTA</strong> profil/GAMMA instabus 5/29<br />
• Design / <strong>DELTA</strong> style/GAMMA instabus 6/24<br />
Unive<strong>rs</strong>al dimmer sys inserts<br />
• Flush-mounting insert for switching <strong>and</strong> dimming different electronic<br />
loads<br />
• It is operated by means of the sys pushbutton or UP 210 wave<br />
pushbutton<br />
• For claw <strong>and</strong> screw fixing<br />
• screw terminals<br />
• 2-wire connection method<br />
• Automatic load detection<br />
• Soft start extends lamp life<br />
• Storing <strong>and</strong> switching on at one brightness value<br />
• Memory value retained even after power failure<br />
• Electronic short-circuit protection <strong>and</strong> overtemperature protection<br />
• On elimination of the short-circuit/cooling, automatic return to normal<br />
mode<br />
• Extension unit operation over conventional pushbuttons<br />
• Number of extension units: Unlimited<br />
• Rated voltage: 230 V AC, 50 Hz<br />
• Connected load, inc<strong>and</strong>escent lamp rating: 50 ... 420 W<br />
• Connected load of conventional transforme<strong>rs</strong>: 50 ... 420 VA<br />
• Connected load of electronic transforme<strong>rs</strong>: 70 ... 420 VA<br />
• Only mixed loads between inc<strong>and</strong>escent lamp ratings <strong>and</strong> electronic<br />
transforme<strong>rs</strong> are permissible.<br />
Symbol For tops see section Page (ff.)<br />
<br />
Design / i-system / Dimme<strong>rs</strong> 1/26<br />
Design / <strong>DELTA</strong> profil/Dimme<strong>rs</strong> 5/22<br />
Design / <strong>DELTA</strong> style/Dimme<strong>rs</strong> 6/19<br />
Note Section Page<br />
For Technical specifications, see ...<br />
Technical Information<br />
/ Dimme<strong>rs</strong> / Unive<strong>rs</strong>al<br />
dimmer sys<br />
inserts<br />
19/19<br />
PU<br />
(UNIT,<br />
S<strong>ET</strong>,<br />
M)<br />
PS*/<br />
P. unit<br />
PG<br />
A 5TC1 233 1 1 unit 024<br />
A 5WG3 560-2AB01 1 1 unit 030<br />
A 5TC1 230 1 1 unit 024<br />
16/6 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />
* You can order this quantity or a multiple thereof.