Remote Control Systems<br />

GAMMA wave — the Multifunctional Radio System<br />

Inserts<br />

© Siemens AG <strong>2011</strong><br />

16<br />

5TC1 233<br />

5WG3 560-2AB01<br />

5TC1 230<br />

Ve<strong>rs</strong>ion DT Order No. Price €<br />

per PU<br />

sys switching inserts, 15 to 500 VA<br />

• The sys switching insert is a flush-mounting device for switching<br />

different electrical consume<strong>rs</strong>, such as<br />

- Inc<strong>and</strong>escent lamps<br />

- HV halogen lamps<br />

- LV halogen lamps with conventional transformer<br />

- LV halogen lamps with electronic transformer<br />

• It is operated by means of the UP 210 wave pushbutton<br />

For tops see section<br />

Page<br />

• Design / i-system / <strong>Switches</strong> <strong>and</strong> Pushbuttons 1/6<br />

• Design / <strong>DELTA</strong> profil/<strong>Switches</strong> <strong>and</strong> Pushbuttons 5/8<br />

• Design / <strong>DELTA</strong> style/<strong>Switches</strong> <strong>and</strong> Pushbuttons 6/6<br />

Product features<br />

• 2-wire connection method<br />

• Spare fuse at the fuse holder<br />

• Overload protection (thermal release)<br />

• Extension unit operation over conventional pushbuttons without glow<br />

lamps<br />

Technical specifications<br />

• Short-circuit protection by miniature T 3.15 A H 250 V<br />

fuse<br />

• Number of extension units Unlimited<br />

• Extension unit cable (total) Max. 100 m<br />

• Rated voltage<br />

230 V AC/50 Hz<br />

• Connected load<br />

- Inc<strong>and</strong>escent lamp rating 15 ... 500 W<br />

- Conventional transforme<strong>rs</strong> (except 15 ... 500 W<br />

toroidal-core transforme<strong>rs</strong>)<br />

- Toroidal-core transforme<strong>rs</strong> 15 ... 250 W<br />

UP 560 wave wall-mounted transmitter "Aktor" 230 V<br />

• Radio transmitter for the wireless operation of room functions, which is<br />

also equipped with a switch actuator for 230 V / 6 A<br />

• For installation in flush-mounting switch boxes<br />

•An instabus KNX/EIB single or double pushbutton is plugged on as<br />

operator interface <strong>and</strong> connected to the insert by means of a 10-pole<br />

plug-in connection<br />

• The following functions can be parameterized: switching, dimming,<br />

shutter/blind <strong>and</strong> scene<br />

• As an additional function, the switch actuator can be operated as a<br />

timer with an adjustable delay time in the range from 1 ... 60 min<br />

• 6 A rated current for resistive load at 230 V AC<br />

• Modular width 71 mm<br />

• Mounting depth 32 mm<br />

For tops see section<br />

Page<br />

• Design / <strong>DELTA</strong> profil/GAMMA instabus 5/29<br />

• Design / <strong>DELTA</strong> style/GAMMA instabus 6/24<br />

Unive<strong>rs</strong>al dimmer sys inserts<br />

• Flush-mounting insert for switching <strong>and</strong> dimming different electronic<br />

loads<br />

• It is operated by means of the sys pushbutton or UP 210 wave<br />

pushbutton<br />

• For claw <strong>and</strong> screw fixing<br />

• screw terminals<br />

• 2-wire connection method<br />

• Automatic load detection<br />

• Soft start extends lamp life<br />

• Storing <strong>and</strong> switching on at one brightness value<br />

• Memory value retained even after power failure<br />

• Electronic short-circuit protection <strong>and</strong> overtemperature protection<br />

• On elimination of the short-circuit/cooling, automatic return to normal<br />

mode<br />

• Extension unit operation over conventional pushbuttons<br />

• Number of extension units: Unlimited<br />

• Rated voltage: 230 V AC, 50 Hz<br />

• Connected load, inc<strong>and</strong>escent lamp rating: 50 ... 420 W<br />

• Connected load of conventional transforme<strong>rs</strong>: 50 ... 420 VA<br />

• Connected load of electronic transforme<strong>rs</strong>: 70 ... 420 VA<br />

• Only mixed loads between inc<strong>and</strong>escent lamp ratings <strong>and</strong> electronic<br />

transforme<strong>rs</strong> are permissible.<br />

Symbol For tops see section Page (ff.)<br />

<br />

Design / i-system / Dimme<strong>rs</strong> 1/26<br />

Design / <strong>DELTA</strong> profil/Dimme<strong>rs</strong> 5/22<br />

Design / <strong>DELTA</strong> style/Dimme<strong>rs</strong> 6/19<br />

Note Section Page<br />

For Technical specifications, see ...<br />

Technical Information<br />

/ Dimme<strong>rs</strong> / Unive<strong>rs</strong>al<br />

dimmer sys<br />

inserts<br />

19/19<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

A 5TC1 233 1 1 unit 024<br />

A 5WG3 560-2AB01 1 1 unit 030<br />

A 5TC1 230 1 1 unit 024<br />

16/6 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

* You can order this quantity or a multiple thereof.