© Siemens AG <strong>2011</strong><br />

Motion Detecto<strong>rs</strong><br />

Inserts<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

5TC1 502<br />

Motion detector extension unit inserts<br />

• Flush-mounting inserts for motion detector tops<br />

• The motion detector extension unit insert is a 3-wire extension unit that can<br />

only be used in combination with a motion detector relay insert or a motion<br />

detector triac insert.<br />

• In case of a motion detection, a brightness-independent switching signal is<br />

issued to the center unit.<br />

• The minimum time between the two switching signals of the motion detector<br />

extension unit insert is approx. 5 sec.<br />

• The evaluation is performed in the top of the center unit.<br />

• The motion detector extension unit must not be assigned to more than one<br />

center unit.<br />

• It is not suitable for the direct switching of loads.<br />

For tops see section<br />

Page<br />

• Design / i-system / Motion Detecto<strong>rs</strong> 1/29<br />

• Design / <strong>DELTA</strong> profil/Motion Detecto<strong>rs</strong> 5/25<br />

• Design / <strong>DELTA</strong> style/Motion Detecto<strong>rs</strong> 6/21<br />

Technical specifications<br />

• Rated voltage<br />

• Connection<br />

• Possible inserts for the center unit<br />

• Extension units<br />

- Number of motion detector<br />

extension unit inserts<br />

230 V AC, 50/60 Hz<br />

N conductor required<br />

To the center unit with motion<br />

detector top<br />

Motion detector relay inserts<br />

(5TC1 500)<br />

Motion detector triac inserts<br />

(5TC1 501)<br />

10<br />

- Maximum cable length (total) 100 m<br />

Note Section Page<br />

Switching comm<strong>and</strong>s are issued by<br />

the release of the plug-on motion<br />

detector top or by an extension unit.<br />

For further details of tops, see ...<br />

Note<br />

Technical Information /<br />

Motion Detecto<strong>rs</strong> /<br />

Motion detector extension<br />

unit inserts<br />

Download the operating <strong>and</strong> mounting instructions from:<br />

http://support.automation.siemens.com/ww/view/en/5tc1502/all<br />

19/45<br />

A 5TC1 502 1 1 unit 024<br />

11<br />

* You can order this quantity or a multiple thereof.<br />

Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

11/3