Technical Information<br />
Shutter/Blind Controls<br />
© Siemens AG <strong>2011</strong><br />
19<br />
Comfort shutter/blind controls<br />
■ Programming<br />
Operating <strong>and</strong> display elements<br />
20<br />
19<br />
18<br />
17<br />
16<br />
15<br />
Uhr<br />
Dat<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
14<br />
Factory settings<br />
1 2 3 4 5 6<br />
Prog Zufall Astro<br />
Mode<br />
A,B,C,/,H<strong>and</strong><br />
13<br />
While program memories A <strong>and</strong> B are factory-assigned, they<br />
can also be user-defined if required. Operating times that are no<br />
longer required must be deleted.<br />
Default factory settings:<br />
• Memory A<br />
- Switching time 1: 07:00, Mo to Fr, astro function active<br />
- Switching time 2: 09:00, Sa to Su, astro function active<br />
- Switching time 3: 20:00, Mo to Fr, astro function active<br />
- Switching time 4: 21:00, Sa to Su, astro function active<br />
• Memory B<br />
- Switching time 1: 07:00, Mo to Fr, astro function not active<br />
- Switching time 2: 09:00, Sa to Su, astro function not active<br />
- Switching time 3: 20:00, Mo to Fr, astro function not active<br />
- Switching time 4: 21:00, Sa to Su, astro function not active<br />
• Memory C<br />
- Not factory assigned.<br />
Mo<br />
Di<br />
Mi<br />
Do<br />
Fr<br />
Sa<br />
So<br />
Independent programs can be stored in the three program<br />
memories A, B <strong>and</strong> C (e.g. for everyday, weekend,<br />
vacations etc.).<br />
Set<br />
s / w<br />
12<br />
Lowering of shutter/blind activated<br />
Raising of shutter/blind activated<br />
Time display<br />
Configuration mode activated<br />
R<strong>and</strong>om function activated<br />
Astro function activated<br />
Minute display<br />
Set day of week<br />
Twilight value underrun<br />
10 Brightness value exceeded<br />
11 Manually execute lowering of shutter/blind<br />
12 Set values<br />
13 Select mode<br />
7<br />
11<br />
14 Manually execute raising of shutter/blind<br />
15 Mode of operation daylight saving time<br />
16 Learn function activated<br />
17 Mode of operation winter time<br />
18 Set date<br />
19 Set time<br />
I2_08808<br />
20 Program memories A/B/C are activated<br />
8<br />
6<br />
10<br />
All three program memories support a maximum of 18 switching<br />
times.<br />
The factory settings can be reset at any time.<br />
Daylight savings<br />
To implement daylight savings, the "Set" button must be briefly<br />
pressed at the appropriate times on the respective dates in<br />
spring <strong>and</strong> fall.<br />
It can also be used to set whether or not any configured individual<br />
motor runtimes are to be executed.<br />
Operating modes<br />
The Comfort shutter/blind clock can be set to the "automatic" <strong>and</strong><br />
"manual" mode. It has three program memories (A, B, C), which<br />
can be alternatively selected in the automatic mode.<br />
• Automatic mode<br />
The set switching times of the program memory A, B or C are<br />
executed. Manual operation is also possible using the / <strong>and</strong><br />
2 buttons. A, B or C is shown on the display.<br />
• Manual operation<br />
Manual operation is only possible by means of the / <strong>and</strong> 2<br />
buttons. The set switching times of the program memories A,<br />
B or C are not executed. A, B or C are not shown on the display.<br />
Automatic mode with program memories A, B, C<br />
In the three program memories, three individual switching time<br />
programs can be generated. By selecting the A, B or C program<br />
memory, the desired switching time program is activated.<br />
By pressing the "Mode" button, it is possible to change between<br />
the program memories (A, B, C) <strong>and</strong> manual operation.<br />
Manual operation<br />
A manual operation is possible with any operating mode. The<br />
shutte<strong>rs</strong>/blinds are raised using the 2 button <strong>and</strong> lowered using<br />
the / button.<br />
During operation, a distinction is made between short <strong>and</strong> long<br />
button strokes:<br />
• Short button stroke (< 1 s)<br />
A pulse is generated in accordance with the duration of the<br />
key operation. This function serves to adjust the blind slats.<br />
• Long button stroke (> 1 s)<br />
The shutter/blind control is set to maintained function (continuous<br />
operation). If no other motor runtimes are programmed,<br />
a runtime of approx. 2 min is executed.<br />
19/56 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010