Technical Information<br />

Shutter/Blind Controls<br />

© Siemens AG <strong>2011</strong><br />

19<br />

Comfort shutter/blind controls<br />

■ Programming<br />

Operating <strong>and</strong> display elements<br />

20<br />

19<br />

18<br />

17<br />

16<br />

15<br />

Uhr<br />

Dat<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

14<br />

Factory settings<br />

1 2 3 4 5 6<br />

Prog Zufall Astro<br />

Mode<br />

A,B,C,/,H<strong>and</strong><br />

13<br />

While program memories A <strong>and</strong> B are factory-assigned, they<br />

can also be user-defined if required. Operating times that are no<br />

longer required must be deleted.<br />

Default factory settings:<br />

• Memory A<br />

- Switching time 1: 07:00, Mo to Fr, astro function active<br />

- Switching time 2: 09:00, Sa to Su, astro function active<br />

- Switching time 3: 20:00, Mo to Fr, astro function active<br />

- Switching time 4: 21:00, Sa to Su, astro function active<br />

• Memory B<br />

- Switching time 1: 07:00, Mo to Fr, astro function not active<br />

- Switching time 2: 09:00, Sa to Su, astro function not active<br />

- Switching time 3: 20:00, Mo to Fr, astro function not active<br />

- Switching time 4: 21:00, Sa to Su, astro function not active<br />

• Memory C<br />

- Not factory assigned.<br />

Mo<br />

Di<br />

Mi<br />

Do<br />

Fr<br />

Sa<br />

So<br />

Independent programs can be stored in the three program<br />

memories A, B <strong>and</strong> C (e.g. for everyday, weekend,<br />

vacations etc.).<br />

Set<br />

s / w<br />

12<br />

Lowering of shutter/blind activated<br />

Raising of shutter/blind activated<br />

Time display<br />

Configuration mode activated<br />

R<strong>and</strong>om function activated<br />

Astro function activated<br />

Minute display<br />

Set day of week<br />

Twilight value underrun<br />

10 Brightness value exceeded<br />

11 Manually execute lowering of shutter/blind<br />

12 Set values<br />

13 Select mode<br />

7<br />

11<br />

14 Manually execute raising of shutter/blind<br />

15 Mode of operation daylight saving time<br />

16 Learn function activated<br />

17 Mode of operation winter time<br />

18 Set date<br />

19 Set time<br />

I2_08808<br />

20 Program memories A/B/C are activated<br />

8<br />

6<br />

10<br />

All three program memories support a maximum of 18 switching<br />

times.<br />

The factory settings can be reset at any time.<br />

Daylight savings<br />

To implement daylight savings, the "Set" button must be briefly<br />

pressed at the appropriate times on the respective dates in<br />

spring <strong>and</strong> fall.<br />

It can also be used to set whether or not any configured individual<br />

motor runtimes are to be executed.<br />

Operating modes<br />

The Comfort shutter/blind clock can be set to the "automatic" <strong>and</strong><br />

"manual" mode. It has three program memories (A, B, C), which<br />

can be alternatively selected in the automatic mode.<br />

• Automatic mode<br />

The set switching times of the program memory A, B or C are<br />

executed. Manual operation is also possible using the / <strong>and</strong><br />

2 buttons. A, B or C is shown on the display.<br />

• Manual operation<br />

Manual operation is only possible by means of the / <strong>and</strong> 2<br />

buttons. The set switching times of the program memories A,<br />

B or C are not executed. A, B or C are not shown on the display.<br />

Automatic mode with program memories A, B, C<br />

In the three program memories, three individual switching time<br />

programs can be generated. By selecting the A, B or C program<br />

memory, the desired switching time program is activated.<br />

By pressing the "Mode" button, it is possible to change between<br />

the program memories (A, B, C) <strong>and</strong> manual operation.<br />

Manual operation<br />

A manual operation is possible with any operating mode. The<br />

shutte<strong>rs</strong>/blinds are raised using the 2 button <strong>and</strong> lowered using<br />

the / button.<br />

During operation, a distinction is made between short <strong>and</strong> long<br />

button strokes:<br />

• Short button stroke (< 1 s)<br />

A pulse is generated in accordance with the duration of the<br />

key operation. This function serves to adjust the blind slats.<br />

• Long button stroke (> 1 s)<br />

The shutter/blind control is set to maintained function (continuous<br />

operation). If no other motor runtimes are programmed,<br />

a runtime of approx. 2 min is executed.<br />