Technical Information<br />

Motion detecto<strong>rs</strong><br />

© Siemens AG <strong>2011</strong><br />

Motion detector tops<br />

Use of the plug-on blind<br />

2<br />

(1,10 m)<br />

1<br />

Using the plug-on blind, sources of interference can be suppressed<br />

by narrowing the sensing range. The blind cove<strong>rs</strong> 90°<br />

of the left or right sensing range.<br />

(2,20 m)<br />

3<br />

2<br />

1<br />

I2_08793<br />

1<br />

2<br />

3<br />

Sensing range<br />

Suppressed range<br />

Blind<br />

■ Programming<br />

Setting the brightness threshold<br />

Setting the sensitivity<br />

Empf.<br />

Empf.<br />

I2_12399<br />

1 2<br />

I2_12399<br />

1 2<br />

1<br />

2<br />

Brightness controller<br />

Sensitivity controller<br />

1<br />

2<br />

Brightness controller<br />

Sensitivity controller<br />

The brightness threshold is the threshold of the brightness at<br />

which a detected movement releases a switching operation.<br />

The brightness threshold can be set within a range of approx.<br />

0 to 80 lux.<br />

To modify the brightness threshold, the controller % must be<br />

turned in the desired direction.<br />

If the controller $ is set to the "sun" limit stop (> 80 lux), the motion<br />

detector top works in day mode <strong>and</strong> switches irrespective of<br />

the current brightness level.<br />

Note: if the motion detector top no longer responds to a detected<br />

motion at the "moon" limit stop (night setting, 0 lux), the controller<br />

$ must be turned slightly in the direction of the sun.<br />

Behavior in case of power failure/recovery<br />

The motion detector top has an internal algorithm which automatically<br />

adjusts the device to ambient conditions. This virtually<br />

eliminates the possibility of unintended switching operations.<br />

Under normal circumstances, the controller should be set to<br />

maximum sensitivity.<br />

If, in exceptional cases, it is necessary to determine a different<br />

sensitivity level, this can be done using the controller %.<br />

Interruption time<br />

Behavior<br />

< 200 ms No change of the switching state.<br />

200 ms … approx. 1 s In case of a power recovery, the duration of the delay time is activated (retriggering)<br />

> approx. 1 s In case of power recovery, auto-test for approx. 60 s<br />

The lighting is switched on for the time of the auto-test.<br />

After the test has been completed, the lighting is switched off <strong>and</strong> the motion detector top is ready for operation.<br />

Behavior when pulling off the motion detector top<br />

The switching state of the insert is retained. If the motion detector<br />

top is plugged on again, it behaves in the same way as after<br />

a power failure of longer than approx. 1 s.<br />