Technical Information<br />

Motion detecto<strong>rs</strong><br />

© Siemens AG <strong>2011</strong><br />

Comfort motion detector tops<br />

Setting the sensitivity<br />

30 min<br />

10 s<br />

10 min 3 min<br />

Empf.<br />

I2_08797<br />

The Comfort motion detector top has an internal algorithm which<br />

carries out an automatic adjustment to the ambient conditions.<br />

This virtually eliminates the possibility of unintended switching<br />

operations.<br />

Under normal circumstances, the controller should be set to<br />

maximum sensitivity.<br />

If, in exceptional cases, it is necessary to determine a different<br />

sensitivity level, this can be done using the controller &.<br />

1 2 3<br />

1<br />

2<br />

3<br />

Overtravel time controller<br />

Brightness controller<br />

Sensitivity controller<br />

■ Schematics<br />

N 1<br />

L N 4<br />

1<br />

2<br />

3<br />

4<br />

5<br />

L<br />

2<br />

1<br />

5<br />

N1 L<br />

I2_08781b<br />

Motion detector relay<br />

insert<br />

Motion detector<br />

extension unit insert<br />

Mechanical pushbutton<br />

without a glow lamp<br />

Connection of further<br />

extension units<br />

Load<br />

3<br />

5TC1 500<br />

5TC1 502<br />

5TD2 120<br />

Caution: It is not permissible to connect motion detector center<br />

units in parallel.<br />

Extension units<br />

The sensing range of a center unit can be extended by means<br />

of extension units. This can be achieved by combining, for<br />

example, a Comfort motion detector top with a motion detector<br />

extension unit insert <strong>and</strong> connecting it to the center unit.<br />

Caution:<br />

• Motion detector extension units are not suitable for the direct<br />

switching of loads but just issue brightness-independent<br />

motion signals to the center unit.<br />

• The brightness threshold, the operating mode <strong>and</strong> the delay<br />

time are set <strong>and</strong> evaluated at the center unit only.<br />

• The operating mode switch <strong>and</strong> the controlle<strong>rs</strong> for brightness<br />

<strong>and</strong> delay time of the Comfort motion detector top on the<br />

extension unit have no function.<br />

• If required, the Comfort motion detector top plugged onto the<br />

extension unit can be adjusted over the respective controller<br />

(see the section Programming).<br />

• When combining the Comfort motion detector top with the motion<br />

detector extension unit insert, please note that after the<br />

lighting has been switched off, there is a locking time of approx.<br />

3 s before the extension unit can be switched on again.<br />

Mechanical pushbuttons<br />

Using mechanical pushbuttons without a glow lamp (NO contact)<br />

& <strong>and</strong> with automatic mode activated, the Comfort motion<br />

detector top can be operated from several sides.<br />

In case of a short operation in the switched off state, the lighting<br />

is switched on irrespective of the current brightness level.<br />

It is not possible to switch off the lighting.<br />

19<br />

19/42 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010