05.01.2015 Views

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

© Siemens AG <strong>2011</strong><br />

Shutter/Blind Controls<br />

Inserts with cover plate<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

5TC1 521<br />

Comfort shutter/blind controls<br />

• For use in the <strong>DELTA</strong> line, <strong>DELTA</strong> vita, <strong>DELTA</strong> miro, <strong>DELTA</strong> profil <strong>and</strong><br />

<strong>DELTA</strong> style ranges<br />

• For controlling a blind or shutter motor with mechanical or electronic limit<br />

switches <strong>and</strong> comprehensive functionality (see product features)<br />

• Menu-controlled operation by means of 4 control buttons<br />

Ve<strong>rs</strong>ions<br />

• Titanium white (similar to RAL 9010) A 5TC1 521 1 1 unit 024<br />

• Electrical white (RAL 1013) A 5TC1 533 1 1 unit 024<br />

• Aluminum metallic or silver (similar to RAL 9006) A 5TC1 523 1 1 unit 024<br />

• Carbon metallic or anthracite (similar to RAL 7016) A 5TC1 525 1 1 unit 024<br />

• Pearl gray (similar to RAL 7035) A 5TC1 556 1 1 unit 024<br />

• Champagne (similar to RAL 7048) A 5TC1 557 1 1 unit 024<br />

• Bronze (similar to RAL 3012) A 5TC1 558 1 1 unit 024<br />

Note Section Page<br />

•The sun sensor must be ordered<br />

separately, see ...<br />

• For use with the <strong>DELTA</strong> profil product<br />

range, the following intermediate<br />

frames must be ordered separately:<br />

- Titanium white (similar to<br />

RAL 9010)<br />

- Silver or aluminum metallic<br />

(similar to RAL 9006)<br />

- Anthracite or carbon metallic<br />

(similar to RAL 7016)<br />

Design / i-system / Accessories<br />

<strong>and</strong> spare parts<br />

Design / <strong>DELTA</strong> profil /<br />

Frames<br />

dto. 5/6<br />

dto. 5/6<br />

1/44 A 5TC1 526 1 1 unit 024<br />

5/6 A 5TG1 893 1 1/10 units 021<br />

A 5TG1 762 1 1/10 units 021<br />

A 5TG1 835 1 1/10 units 021<br />

- Pearl gray (similar to RAL 7035) dto. 5/6 A 5TG1 885 1 1/10 units 021<br />

- Champagne (similar to RAL 7048) dto. 5/6 A 5TG1 705-1 1 1/10 units 021<br />

- Bronze (similar to RAL 3012) dto. 5/6 A 5TG1 745-1 1 1/10 units 021<br />

• For use with the <strong>DELTA</strong> style product Design / <strong>DELTA</strong> style/<br />

range, titanium white, an intermediate<br />

frame must be ordered separate-<br />

Frames<br />

ly, see ...<br />

• For Technical specifications, see ...<br />

Note<br />

Technical Information /<br />

Shutter/Blind Controls /<br />

Comfort shutter/blind controls<br />

Download the operating <strong>and</strong> mounting instructions from:<br />

http://support.automation.siemens.com/ww/view/en/5tc1521/all<br />

Product features<br />

6/5 A 5TG1 327 1 1/10 units 021<br />

19/54<br />

• Flush-mounting device without an extension unit input<br />

• 230 V AC, 50 Hz (N conductor required)<br />

• With screw <strong>and</strong> claw fixing<br />

• Type of connection: screw terminals<br />

• 2 relays which are electrically interlocked against each other with a<br />

minimum switchover time of approx. 1 s<br />

• Bridging of voltage interruptions < 0.2 s<br />

• Connected load: max. 1 motor up to 1000 W<br />

• Pulse duration: 2 min factory setting, may be changed to<br />

as much as 12 min by programming<br />

• Accuracy: ± 1 min per month<br />

• Reserve power: approx. 24 h<br />

• Switching times: max. 18 (can be split up in three memories)<br />

• Factory preset switching times for faster commissioning<br />

• Possible reset to factory settings<br />

• R<strong>and</strong>om generator ± 15 min<br />

• Astro program (can be delayed by ± 1 h 59 min)<br />

• Easy changeover to daylight savings<br />

• Twilight <strong>and</strong> sun protection function is possible with an optional sun sensor<br />

• The r<strong>and</strong>om <strong>and</strong> astro functions can be combined<br />

• Manual operation possible at any time<br />

13<br />

* You can order this quantity or a multiple thereof.<br />

Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

13/9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!