05.01.2015 Views

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens AG <strong>2011</strong><br />

Switching/Pushbutton Control/Dimming<br />

Inserts<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

5TC1 233<br />

5TC8 604<br />

sys switching inserts, 15 to 500 VA<br />

• The sys switching insert is a flush-mounting device for switching different<br />

electrical consume<strong>rs</strong>, such as<br />

- Inc<strong>and</strong>escent lamps<br />

- HV halogen lamps<br />

- LV halogen lamps with magnetic transformer<br />

- LV halogen lamps with electronic transformer<br />

• It is operated using UP 210 wave pushbuttons (radio waves)<br />

For tops see section<br />

Page (ff.)<br />

• Design / i-system / Lighting Controls 1/26<br />

• Design / <strong>DELTA</strong> profil/Lighting Controls 5/22<br />

• Design / <strong>DELTA</strong> style/Lighting Controls 6/19<br />

Product features<br />

• 2-wire connection method<br />

• Spare fuse at the fuse holder<br />

• Overload protection (thermal release)<br />

• Extension unit operation over conventional pushbuttons without glow<br />

lamps<br />

Technical specifications<br />

• Short-circuit protection by miniature<br />

T3.15 A H 250 V<br />

fuse<br />

• Number of extension units Unlimited<br />

• Extension unit cable (total) Max. 100 m<br />

• Rated voltage<br />

230 V AC/50 Hz<br />

• Connected load<br />

- Inc<strong>and</strong>escent lamp rating 15 ... 500 W<br />

- Conventional transforme<strong>rs</strong> (except<br />

15 ... 500 VA<br />

toroidal-core transforme<strong>rs</strong>)<br />

- Toroidal-core transforme<strong>rs</strong> 15 ... 250 VA<br />

- Electronic transforme<strong>rs</strong> 15 ... 500 VA<br />

•Approvals<br />

VDE certification<br />

Speed regulating rheostats, 0.1 to 2.6 A<br />

• For speed control of fans <strong>and</strong>/or other devices with single-phase induction<br />

motor<br />

• 230 V AC, 50/60 Hz<br />

• With rotary ON/OFF switch <strong>and</strong> rotary operation<br />

• For claw <strong>and</strong> screw fixing<br />

• Screw terminals with anti-slip terminal body for solid <strong>and</strong> finely str<strong>and</strong>ed<br />

conducto<strong>rs</strong><br />

• Miniature fuse T 4 H 250 V with spare fuse in fuse holder<br />

• Order no. for spare fuse: 5TG8 330<br />

• With temperature cutout, not resettable<br />

• Trimming potentiometer for minimum speed<br />

• VDE <strong>and</strong> KEMA certification<br />

Symbol For tops see section Page (ff.)<br />

Design / i-system / Lighting Controls 1/26<br />

Design / <strong>DELTA</strong> profil/Lighting Controls 5/22<br />

Design / <strong>DELTA</strong> style/Lighting Controls 6/19<br />

Note Section Page<br />

For Technical specifications, see ... Technical Information /<br />

Dimme<strong>rs</strong> / Speed regulating<br />

rheostats, 0.1 ... 2.6 A<br />

Inserts for add-on devices<br />

Time switches<br />

•For screw fixing<br />

• 16 A, 250 V AC<br />

• Runtime: 15 min<br />

• Can be switched off<br />

•2-pole<br />

For tops see section<br />

19/30<br />

• Design / <strong>DELTA</strong> style/Accessories <strong>and</strong> spare parts 6/19<br />

Page (ff.)<br />

A 5TC1 233 1 1 unit 024<br />

A 5TC8 604 1 1 unit 024<br />

A 5TC1 250 1 1 unit 024<br />

10<br />

5TC1 250<br />

* You can order this quantity or a multiple thereof.<br />

Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

10/17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!