© Siemens AG <strong>2011</strong><br />

Switching/Pushbutton Control/Dimming<br />

Complete assemblies<br />

■ Selection <strong>and</strong> ordering data<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

10<br />

5TT3 303<br />

5WG1 528-1AB41<br />

Dusk switches<br />

• Setting range 2 ... 2000 Lux<br />

• 1-channel ve<strong>rs</strong>ion for surface mounting, IP55<br />

• With integrated light sensor<br />

Technical specifications<br />

• Rated control voltage U c 230 V AC<br />

• Operating range × U c at 50/60 Hz 0.85 ... 1.1<br />

• Rated frequency<br />

50 Hz<br />

• Time delay (fixed)<br />

•Contact<br />

• Rated operational voltage U e<br />

50 s<br />

1 NO contact<br />

250 V AC<br />

• Rated operational current I s<br />

- at p.f. = 1 10<br />

- at p.f. = 0.4 2<br />

• Inc<strong>and</strong>escent lamp rating 1200 W<br />

• Minimum contact load<br />

10 V, 100 mA<br />

•Terminals 1<br />

• Conductor cross-section<br />

- Rigid 1.5 mm 2<br />

- Flexible with sleeve Min. 0.5 mm 2<br />

• Resistance to climate acc. to<br />

DIN 50016<br />

• Degree of protection acc. to<br />

EN 60529<br />

• Safety class acc. to EN 61010<br />

FW 24<br />

IP54<br />

Note Section Page<br />

For dimensional drawings, see ... Technical Information /<br />

<strong>Switches</strong> <strong>and</strong> Pushbuttons /<br />

Dusk switches<br />

II<br />

19/11<br />

Unive<strong>rs</strong>al dimmer expansions<br />

• One output for the switching <strong>and</strong> dimming of resistive, inductive or<br />

capacitive loads<br />

• Rated operational voltage: 230 V AC, 50/60 Hz<br />

• Rated power at +45 °C ambient temperature: 20 ... 300 VA or<br />

20 ... 500 VA or 20 ... 1000 VA<br />

• Two extension unit inputs for 230 V AC (with neutral conductor as<br />

ground) for switching <strong>and</strong> dimming of the output <strong>and</strong> optional transmission<br />

of switching <strong>and</strong> dimming comm<strong>and</strong>s via the bus<br />

• Automatic adjustment to leading-edge or trailing-edge phase control,<br />

depending on the connected load type<br />

• Electronic protection of output against overload <strong>and</strong> short-circuit <strong>and</strong><br />

overtemperature<br />

• Max. length of connecting leads to extension unit inputs: 100 m<br />

• Width 3 MW (1 MW = 18 mm)<br />

VA<br />

Type<br />

C 5TT3 303 1 1 unit 027<br />

20 ... 300 N 528/41 B 5WG1 528-1AB41 1 1 unit 030<br />

20 ... 500 N 527/41 B 5WG1 527-1AB41 1 1 unit 030<br />

20 ... 1000 N 527/51 B 5WG1 527-1AB51 1 1 unit 030<br />

Symbol<br />

<br />

Technical product specifications<br />

www.siemens.com/gamma-td<br />

10/18 Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

* You can order this quantity or a multiple thereof.