© Siemens AG <strong>2011</strong><br />

Technical Information<br />

Motion detecto<strong>rs</strong><br />

Motion detector relay inserts (5TC1 500)<br />

■ Design<br />

I2_08810<br />

1<br />

2<br />

3<br />

4<br />

Motion detector<br />

relay insert<br />

Frame<br />

Motion detector top<br />

Plug<br />

4<br />

3<br />

1<br />

2<br />

Plug on the motion detector top prior to applying the supply voltage.<br />

Do not replace the motion detector top if the insert is connected<br />

to the power supply as this will cause a malfunction.<br />

Power losses > 1 s lead to a switch-off of the motion detector relay<br />

insert.<br />

Connect an upstream miniature circuit breaker 10 A for device<br />

protection.<br />

Observe the maximum connected load <strong>and</strong> the load specifications<br />

contained in the technical specifications.<br />

Depending on the mounting type, the max. connected load must<br />

be reduced by:<br />

• –10 % each time the ambient temperature of 25 °C is<br />

exceeded by 5 °C,<br />

• –15 % for mounting on wood, Rigips or cavity walls,<br />

• –20 % for mounting in multiple combinations.<br />

The motion detector relay insert $ is mounted in a DIN 49073-<br />

compliant device box.<br />

The terminals of the motion detector relay insert must be directed<br />

downwards (for wall mounting).<br />

Only use the motion detector relay insert in combination with a<br />

motion detector top. Plug the motion detector top & together<br />

with the frame % onto the insert. The electrical contacting is<br />

achieved over the plug (.<br />

Use of extension units<br />

The sensing field of the center unit can be extended by means<br />

of the motion detector extension unit insert.<br />

If mechanical pushbuttons are used (NO contacts), the lighting<br />

can be switched on from several sides irrespective of the current<br />

brightness level.<br />

Note: A motion detector top must be mounted on the center unit<br />

- otherwise, there will be no function. A motion detector extension<br />

unit insert <strong>and</strong> a mechanical pushbutton without a glow<br />

lamp can be connected to a center unit in combination.<br />

■ Schematics<br />

5<br />

1<br />

N 1<br />

L<br />

5TC1 500<br />

L<br />

N<br />

230 V AC 50/60 Hz<br />

5TC1 500<br />

1<br />

2<br />

N1 L<br />

5TC1 502<br />

2<br />

N 1<br />

L<br />

3<br />

I2_08780a<br />

5TD2 120<br />

1<br />

Motion detector<br />

relay insert<br />

I2_08781b<br />

2<br />

Load<br />

L N 4<br />

Connection of motion detector relay inserts<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Motion detector relay<br />

insert<br />

Motion detector<br />

extension unit insert<br />

Mechanical pushbutton<br />

without a glow lamp<br />

Connection of further<br />

extension units<br />

Load<br />

Connection of all possible inserts<br />

19<br />