05.01.2015 Views

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

© Siemens AG <strong>2011</strong><br />

Shutter/Blind Controls<br />

Inserts<br />

Ve<strong>rs</strong>ion DT Order No. Price<br />

per PU<br />

PU<br />

(UNIT,<br />

S<strong>ET</strong>,<br />

M)<br />

PS*/<br />

P. unit<br />

PG<br />

5TC1 231<br />

5TC1 270<br />

sys shutter/blind control inserts<br />

• For controlling a shutter/blind motor with mechanical or electronic limit<br />

switches<br />

• Flush-mounting devices<br />

• Operation is by means of sys shutter/blind pushbuttons <strong>and</strong> UP 211 wave<br />

shutter/blind pushbuttons (radio)<br />

Product features<br />

• 2 relays which are interlocked against each other with a minimum switchover<br />

time of 1 s<br />

• Group <strong>and</strong> central controls through combination of several shutter/blind<br />

control sys inserts<br />

• The "wind alarm" safety function can be implemented through the<br />

UP extension unit input<br />

• Multiphase operation possible (i.e. different phases at the main <strong>and</strong><br />

secondary branches)<br />

• Bridging of voltage interruptions less than 0.2 s<br />

• Conventional shutter/blind pushbuttons (5TA2 114) or switches (5TA2 154)<br />

can be connected over secondary inputs<br />

• Number of extension units: Unlimited<br />

• Rated voltage: 230 V AC, 50 Hz (neutral conductor required)<br />

• Connected load: max. 1 motor up to 1000 VA<br />

For tops see section<br />

Page (ff.)<br />

• Design / i-system / Shutter/Blind Controls 1/21<br />

• Design / <strong>DELTA</strong> profil / Shutter/Blind Controls 5/18<br />

• Design / <strong>DELTA</strong> style / Shutter/Blind Controls 6/16<br />

Note Section Page<br />

For Technical specifications, see ... Technical Information /<br />

Shutter/Blind Controls / sys<br />

shutter/blind control inserts<br />

Note<br />

Download the operating <strong>and</strong> mounting instructions from:<br />

http://support.automation.siemens.com/ww/view/en/5tc1231/all<br />

19/51<br />

A 5TC1 231 1 1 unit 024<br />

Shutter/blind control flush-mounting isolating relays<br />

• Double, with individual control<br />

• Relay for the control of several shutte<strong>rs</strong> or blinds<br />

• Two moto<strong>rs</strong> can be controlled per isolating relay, even if further isolating<br />

relays are connected downstream<br />

• Option for individual control of connected moto<strong>rs</strong> over shutter/blind pushbutton<br />

(e.g. 5TA2 114)<br />

• In order to ensure a sufficient degree of protection, the isolating relay must<br />

be installed in a surface-mounting or flush-mounting box<br />

A 5TC1 270 1 1 unit 024<br />

Technical specifications<br />

• Rated voltage 230 V/50 Hz ±10 %<br />

• Relay switching voltage Max. 250 V<br />

• Relay switching capacity Max. 8 A (AC1), 3 A (ind.)<br />

• Control voltage 230 V AC ±10 %<br />

• Relay power consumption 10 mA<br />

• Temperature range 0 ... 60 °C<br />

•Terminals Max. 2.5 mm 2<br />

• Dimensions<br />

58 mm x 59 mm x 22 mm<br />

•Weight<br />

Approx. 75 g<br />

• Mounting Flush-mounting box from 70 mm Ø,<br />

4 mm deep or surface-mounting box,<br />

100 mm x 100 mm<br />

• Interlock to prevent simultaneous actuation of central <strong>and</strong> individual<br />

control<br />

• Priority switching of the central comm<strong>and</strong><br />

• The switchover time between an UP <strong>and</strong> DOWN comm<strong>and</strong> must be at least<br />

0.5 sec<br />

• Only for in-phase operation<br />

Note Section Page<br />

For further technical information,<br />

see ...<br />

Note<br />

Technical Information /<br />

Shutter/Blind Controls /<br />

Shutter/blind control flushmounting<br />

isolating relays<br />

Download the operating <strong>and</strong> mounting instructions from:<br />

http://support.automation.siemens.com/ww/view/en/5tc1270/all<br />

19/58<br />

13<br />

* You can order this quantity or a multiple thereof.<br />

Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />

13/3