DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
DELTA Switches and Socket Outlets Catalog ET D1 · 2011 - Sobel.rs
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
© Siemens AG <strong>2011</strong><br />
Remote Control Systems<br />
GAMMA wave — the Multifunctional Radio System<br />
Inserts<br />
■ Selection <strong>and</strong> ordering data<br />
5WG3 141-2AB01<br />
5WG3 110-2AB11<br />
5WG3 110-2AB01<br />
5TC1 232<br />
Ve<strong>rs</strong>ion DT Order No. Price €<br />
per PU<br />
UP 141 wave repeate<strong>rs</strong><br />
• Radio transmitter/receiver<br />
• Sends on each correctly received radio telegram<br />
• For installation in flush-mounting switch boxes<br />
• A repeater is needed in large residential units or houses when radio<br />
telegrams are so weakened by walls, ceilings or furniture that an assigned<br />
receiver is no longer able to receive the telegrams properly<br />
• The repeater is powered from the 230 V supply<br />
• Modular width 71 mm<br />
• Mounting depth 32 mm<br />
• A blanking cover plate is used as the top<br />
For tops see section<br />
Page<br />
• Design / i-system / Add-On Devices 1/41<br />
• Design / <strong>DELTA</strong> profil/Add-On Devices 5/39<br />
• Design / <strong>DELTA</strong> style/Add-On Devices 6/34<br />
UP 110 wall-mounted transmitter 230 V wave<br />
• Radio transmitter for the wireless operation of room functions<br />
• For installation in flush-mounting switch boxes<br />
•An instabus KNX/EIB single or double pushbutton is plugged on as<br />
operator interface <strong>and</strong> connected to the insert by means of a 10-pole<br />
plug-in connection<br />
• The following functions can be parameterized: switching, dimming,<br />
shutter/blind <strong>and</strong> scene<br />
• The wall-mounted transmitter is powered from the 230 V supply<br />
• Modular width 71 mm<br />
• Mounting depth 32 mm<br />
For tops see section<br />
Page<br />
• Design / <strong>DELTA</strong> profil/GAMMA instabus 5/29<br />
• Design / <strong>DELTA</strong> style/GAMMA instabus 6/24<br />
UP 110 wave wall-mounted transmitter "Batterie"<br />
• Radio transmitter for the wireless operation of room functions<br />
• For installation in flush-mounting switch boxes<br />
•An instabus KNX/EIB single or double pushbutton is plugged on as<br />
operator interface <strong>and</strong> connected to the insert by means of a 10-pole<br />
plug-in connection<br />
• The following functions can be parameterized: switching, dimming,<br />
shutter/blind <strong>and</strong> scene<br />
• The wall-mounted transmitter is powered by a 1/2 AA 3.6 V lithium<br />
battery<br />
• Modular width 71 mm<br />
• Mounting depth 24 mm<br />
For tops see section<br />
Page<br />
• Design / <strong>DELTA</strong> profil/GAMMA instabus 5/29<br />
• Design / <strong>DELTA</strong> style/GAMMA instabus 6/24<br />
sys switching inserts, 25 to 250 VA<br />
• The sys switching insert is a flush-mounting device for switching<br />
different electrical consume<strong>rs</strong>, such as<br />
- Inc<strong>and</strong>escent lamps<br />
- HV halogen lamps<br />
- LV halogen lamps with conventional transformer<br />
- LV halogen lamps with electronic transformer<br />
• It is operated by means of the UP 210 wave pushbutton<br />
For tops see section<br />
Page<br />
• Design / i-system / <strong>Switches</strong> <strong>and</strong> Pushbuttons 1/6<br />
• Design / <strong>DELTA</strong> profil/<strong>Switches</strong> <strong>and</strong> Pushbuttons 5/8<br />
• Design / <strong>DELTA</strong> style/<strong>Switches</strong> <strong>and</strong> Pushbuttons 6/6<br />
Product features<br />
• 2-wire connection method<br />
• Spare fuse at the fuse holder<br />
• Overload protection (thermal release)<br />
• Extension unit operation over conventional pushbuttons without glow<br />
lamps<br />
Technical specifications<br />
• Short-circuit protection by miniature T 3.15 A H 250 V<br />
fuse<br />
• Number of extension units Unlimited<br />
• Extension unit cable (total) Max. 100 m<br />
• Rated voltage<br />
230 V AC/50 Hz<br />
• Connected load<br />
- Inc<strong>and</strong>escent lamp rating 25 ... 250 W<br />
- Conventional transforme<strong>rs</strong> 25 ... 250 W<br />
- Electronic transforme<strong>rs</strong> 25 ... 250 W<br />
PU<br />
(UNIT,<br />
S<strong>ET</strong>,<br />
M)<br />
PS*/<br />
P. unit<br />
PG<br />
A 5WG3 141-2AB01 1 1 unit 030<br />
B 5WG3 110-2AB11 1 1 unit 030<br />
A 5WG3 110-2AB01 1 1 unit 030<br />
A 5TC1 232 1 1 unit 024<br />
16<br />
* You can order this quantity or a multiple thereof.<br />
Siemens <strong>ET</strong> <strong>D1</strong> · 10/2010<br />
16/5