***)<br />
supply voltage and operating temperature: To achieve T amb max = 70°C and, for example, GSM<br />
900 PCL 5 the supply voltage must not be higher than 4.2V.<br />
To achive T amb max = 70°C at permanent GPRS class 8 operation (1 TX, 4 RX GSM 900 at<br />
PCL 5 with a supply voltage 4.2V) it is recommended to integrate XT55/56 in such a way that a<br />
minor heat exchange with the environment can take place. A solution might be the usage of a<br />
small heat sink.<br />
XT55/56_hd_v02.06a Page 88 of 125 17.12.2004