Frequency isolator / transformer with alarm function – Overview<br />

Process monitoring<br />

The UPI-SERIES – frequency isolator / transformer with<br />

alarm function<br />

F<br />

The frequency isolators with alarm function from the UPI-SERIES<br />

convert standard analogue current and voltage signals into a<br />

proportional frequency. Measurement errors (which can occur<br />

with low input frequencies) are eliminated with a programmable<br />

frequency suppression. In addition, a quadratic function linearizes<br />

the signals. External passive sensors can be supplied directly<br />

via the analogue frequency isolating transformer. An alarm<br />

output is available for monitoring the input signal. The fourcharacter<br />

LED display can be set universally. The corresponding<br />

scaling for the input parameters is then carried out automatically.<br />

The user-friendly menus are easy and navigate and make it<br />

easy to configure the operating parameters. Specific parameters<br />

can be selected and changed using the keyboard and display.<br />

The analogue frequency isolating transformer from the<br />

UPI-SERIES feature complete 2-kV electrical isolation. Wires are<br />

connected on the front side with a pluggable screw mechanism.<br />

The modules can be directly mounted on TS35/TS32 DIN rails.<br />

Typical application of UPI-SERIES<br />

<strong>Analogue</strong> frequency isolating transformer<br />

Pipeline<br />

4...20 mA input<br />

(proportional to rate)<br />

Flow-rate<br />

transmitter<br />

UPIT<br />

Technical features<br />

24 V DC<br />

C<br />

Power supply<br />

Variable frequency<br />

pulse output<br />

proportional to volume<br />

e.g. 100 pulses per min<br />

Fluid flow – max. 60,000 L/hr<br />

Low-flow alarm<br />

Flow Interator<br />

(volume counter)<br />

Counter indicates<br />

accumulated litres<br />

with factor x10<br />

• Configurable analogue frequency output<br />

• Supplies external passive loop-powered sensors<br />

• Alarm output via relay and LED status display<br />

• LED display can be parameterised according to a physical<br />

unit system.<br />

• Live configuration using membrane push buttons for the<br />

input/output parameters, display areas and alarm settings<br />

• Complete 3-way electrical isolation<br />

• Pluggable screw connection mechanism<br />

• Sturdy metal housing for mounting on DIN-rail<br />