19.01.2015 Views

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Process monitoring with relay output<br />

DPA-SERIES<br />

Universal, galvanically-isolated signal converters<br />

with alarm function and two setpoint adjustments.<br />

• Two alarm channels<br />

• External power supply<br />

• Pluggable connection terminals<br />

• Compact enclosure<br />

DPADMV<br />

Voltage monitoring 0...10(100) mV<br />

Process monitoring<br />

• For voltage signals [mV DC]<br />

• High input impedance<br />

0 V +24 V<br />

9 10<br />

L<br />

H<br />

• Bi-polar input signals on request<br />

+<br />

2<br />

4<br />

Vin<br />

0 V<br />

V<br />

PS<br />

Ch 1<br />

Ch 2<br />

NC<br />

11<br />

Common<br />

12<br />

NO<br />

13<br />

NC<br />

14<br />

Common<br />

15<br />

NO<br />

16<br />

Technical data<br />

Connections<br />

Input<br />

Type<br />

Input signal<br />

Input resistance, voltage/current<br />

Input range<br />

Offset<br />

Output digital<br />

Type<br />

Number of channels<br />

Switching current<br />

Settings<br />

Fine adjustment<br />

Hysteresis<br />

Range of adjustment<br />

General data<br />

Supply voltage<br />

Power consumption<br />

Repeat accuracy<br />

Long-term drift<br />

Humidity<br />

Temperature coefficient<br />

Step response time<br />

Ambient temperature / Storage temperature<br />

Approvals<br />

Insulation coordination<br />

Impulse withstand voltage<br />

Insulation voltage<br />

EMC standards<br />

Voltages (≤ 100 mV)<br />

0–10 mV or 0–100 mV<br />

10 MΩ /<br />

8…100 mV DC<br />

0...500 % of signal range<br />

Relay output, change-over contact<br />

2<br />

3 A @ 240 V AC, 3 A @ 24 V DC / 110 V AC<br />

Potentiometer, 20 turns<br />

1...25 % of max. input value<br />

0 - 100 % of max. input value<br />

24 V DC ± 10 %<br />

3 W @ 24 V DC<br />

± 0.05 % of signal range<br />

0.1 % / 10.000 h<br />

0 to 90 % (no condensation)<br />

< 0.04 % / °C<br />

typ. 5 ms<br />

0 °C...+60 °C / -25 °C...+70 °C<br />

cULus; CE<br />

4 kV (1.2/50 µs)<br />

2 kV input / output / power supply<br />

DIN EN 61326<br />

Terminal <strong>Signal</strong><br />

1 Unassigned<br />

2 <strong>Signal</strong> +<br />

3 Unassigned<br />

4 <strong>Signal</strong> –<br />

F<br />

Dimensions<br />

Clamping range (nominal / min. / max.)<br />

Length x width x height<br />

Note<br />

mm²<br />

mm<br />

Screw connection<br />

1.5 / 0.5 / 2.5<br />

120 / 46 / 97<br />

PE connection direct on enclosure<br />

Ordering data<br />

Connection system<br />

Voltage input<br />

Voltage input<br />

Type Qty. Order No.<br />

DPADMV 0-100mV 1 7940017849<br />

DPADMV 0-10mV 1 7940017848<br />

Note<br />

Accessories<br />

F.27

Hooray! Your file is uploaded and ready to be published.