19.01.2015 Views

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Frequency isolator / transformer with alarm function<br />

Process monitoring<br />

Micromann UPI-SERIES<br />

Analog frequency converter for all standard<br />

current and voltage signals<br />

• Frequency pulse output<br />

• 24 V DC supply of the active input device<br />

• Integrated linearisation<br />

• Pluggable connection terminals<br />

UPIR<br />

Low frequency output [relay]<br />

• Frequencies up to 25 Hz<br />

• 1-pole change-over switch with relay contact/<br />

0 V +24 V<br />

9 10<br />

L<br />

H<br />

frequency output and alarm channel<br />

1<br />

2<br />

+<br />

3<br />

4<br />

+<br />

+24 V<br />

Iin<br />

0 V<br />

Vin<br />

V/I<br />

PS<br />

f<br />

NC<br />

Common<br />

NO<br />

fout NC<br />

+ fout Common<br />

fout NO<br />

–<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

Technical data<br />

Connections<br />

F<br />

Input<br />

Input signal<br />

Input resistance, voltage/current<br />

Sensor supply<br />

Resolution<br />

Output<br />

Type<br />

Output frequency<br />

Alarm output<br />

Type<br />

Switching current<br />

-55...+55 mA / -55...+55 V<br />

22 Ω / 1 MΩ<br />

24 V DC (up to 25 mA)<br />

1 µA/1 mV per bit<br />

Frequency-controlled relay output (CO)<br />

≤ 25 Hz<br />

Relay output (CO)<br />

3 A @ 240 V AC (resistive load)<br />

Terminal <strong>Signal</strong><br />

11 Normally closed<br />

12 Common Alarm output<br />

13 Normally open<br />

14 Normally closed<br />

15 Common Freqency output<br />

16 Normally open<br />

Switching thresholds<br />

Display<br />

Type<br />

Display range<br />

Display value<br />

General data<br />

Supply voltage<br />

Linearity<br />

Accuracy<br />

Repeat accuracy<br />

Temperature coefficient<br />

Long-term drift<br />

Step response time<br />

3 A @ 24 V DC / 110 V AC (resistive load)<br />

Adjustable<br />

4 digits, red LED, 7 mm<br />

0...9999<br />

Output frequency per s, min or h<br />

12...50 V DC<br />

± 0.1 % typ.<br />

< 0,1 %<br />

± 0.05 % of signal range<br />

≤ 0.02 % / °C<br />

0.1 % / 10.000 h<br />

320 ms (10...90 %),<br />

Approvals<br />

Insulation coordination<br />

Insulation voltage<br />

Impulse withstand voltage<br />

EMC standards<br />

adjustable to 250 ms...32 s<br />

cULus; CE<br />

2 kV input / output / power supply<br />

4 kV (1.2/50 µs)<br />

DIN EN 61326<br />

Dimensions<br />

Clamping range (nominal / min. / max.)<br />

Length x width x height<br />

Note<br />

mm²<br />

mm<br />

Screw connection<br />

1.5 / 0.5 / 2.5<br />

120 / 46 / 97<br />

PE connection direct on enclosure<br />

Ordering data<br />

Frequency converter<br />

Type Qty. Order No.<br />

UPIR 1 7940010908<br />

Note<br />

Accessories<br />

F.14