Glossary<br />

Technical appendix/Glossary<br />

Measuring bridge<br />

Sensors based on Wheatstone bridge circuitry can capture force, pressure and<br />

torque. Relatively small length changes under 10 – 4 mm can be recorded using<br />

DMS strain gauges in the form of resistance changes. A typical application is for<br />

capturing measurements in load cells.<br />

N<br />

Namur sensor<br />

NEC 500 – 505<br />

Nominal switching current – load side<br />

Nominal switching voltage – load side<br />

NAMUR-compliant sensors (The standardization commission for measuring<br />

and control technology in the German chemical industry) operate with a loadindependent<br />

current. They have four modes so that an analogue evaluative unit can<br />

detect a sensor malfunction.<br />

1) Current of 0 mA => wire break, circuit is open<br />

2) Current of approx. 20 % of the max. value => Sensor ready, activated<br />

3) Current of approx. 60 % of the max. value => Sensor ready, not activated<br />

4) Current at max. value => short circuit, max. current<br />

NAMUR sensors are suited for use in hazardous areas.<br />

The relevant directives for the classification of explosion protection in the USA.<br />

NEC 500 regulates the standard Ex classifications (class – division – model). The<br />

NEC 505 defines the zone model based on the European and IEC classifications.<br />

The permitted load current of a relay contact or semiconductor contact when in<br />

continuous operations.<br />

The switching voltage that a relay contact or semiconductor contact uses in relation<br />

to its application.<br />

O<br />

Output-current loop-powered<br />

Output loop powered 2-wire transmitters have a 4 – 20 mA output. The transmitter<br />

is supplied with power via the current loop on the output side. A typical loop consists<br />

of a regulated DC power supply, the 2-wire transmitter and a receiving device.<br />

W<br />

W.33