Process monitoring with relay output and display<br />

Micromann R-SERIES<br />

Universal, galvanically-isolated signal<br />

converters with alarm function and two setpoint<br />

adjustments.<br />

• Two alarm channels<br />

• External power supply<br />

• Pluggable connection terminals<br />

• Compact enclosure<br />

CNDR<br />

Conductivity monitoring<br />

Process monitoring<br />

• Suitable for all conductivity probes<br />

• Automatic measuring range selection<br />

0 V +24 V<br />

9 10<br />

L<br />

H<br />

• Compensation for probe temperature<br />

• Programmable cell constant<br />

• Linearized probe characteristic<br />

2<br />

3<br />

Conductivity A<br />

Conductivity B<br />

4 A<br />

5 B<br />

6 Bsense<br />

S/J<br />

PS<br />

Ch 1<br />

Ch 2<br />

NC<br />

11<br />

Common<br />

12<br />

NO<br />

13<br />

NC<br />

14<br />

Common<br />

15<br />

NO<br />

16<br />

Technical data<br />

Connections<br />

Input<br />

Input signal<br />

0...200 µS (0.1 µS resolution)<br />

Terminal <strong>Signal</strong><br />

1 Unassigned<br />

0...1000 / 5000 µS (1 µS resolution)<br />

2 A Conductivity<br />

Supply voltage<br />

Battery constant<br />

Cable-length compensation<br />

Alarm output<br />

Type<br />

Switching current<br />

Switching thresholds<br />

Display<br />

Type<br />

Display value<br />

Display range<br />

Resolution (display)<br />

General data<br />

Supply voltage<br />

Temperature coefficient<br />

Long-term drift<br />

Step response time<br />

0...20 mS (0.01 mS resolution)<br />

≤ 6 V ss<br />

@ 400 Hz<br />

0.01...99.99 / cm<br />

< 2 % (up to 30 Ω)<br />

CO contact<br />

1 A @ 240 V AC / 30 V DC (resistive load)<br />

All values in display range are configurable<br />

4 digits, red LED, 7 mm<br />

µS, mS, µS/cm, mS/cm or °C<br />

Depends on selected input signal<br />

0.1 µS / 1 µS / 0.01 mS / 0.1 °C<br />

12...50 V DC<br />

≤ 0.02 % / °C<br />

0.1 % / 10.000 h<br />

320 ms (10...90 %),<br />

3 B Conductivity<br />

4 A Temperature<br />

5 B Temperature<br />

6 B-Sense Temperature<br />

F<br />

Ambient temperature / Storage temperature<br />

Approvals<br />

Insulation coordination<br />

Impulse withstand voltage<br />

Insulation voltage<br />

EMC standards<br />

adjustable to 250 ms...32 s<br />

0 °C...+60 °C / -25 °C...+70 °C<br />

cULus; CE<br />

4 kV (1.2/50 µs)<br />

2 kV input / output / power supply<br />

DIN EN 61326<br />

Dimensions<br />

Clamping range (nominal / min. / max.)<br />

Length x width x height<br />

Note<br />

mm²<br />

mm<br />

Screw connection<br />

1.5 / 0.5 / 2.5<br />

120 / 46 / 97<br />

PE connection direct on enclosure<br />

Ordering data<br />

Relay output<br />

Type Qty. Order No.<br />

CNDR 1 7940017921<br />

Note<br />

Accessories<br />