19.01.2015 Views

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

Каталог Weidmuller: Electronics - Analogue Signal Conditioning

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Process monitoring with relay output<br />

Process monitoring<br />

DPA-SERIES<br />

Universal, galvanically-isolated signal converters<br />

with alarm function and two setpoint adjustments.<br />

• Two alarm channels<br />

• External power supply<br />

• Pluggable connection terminals<br />

• Compact enclosure<br />

DPARTD<br />

Temperature monitoring (RTD)<br />

• For temperature signals [°C]<br />

• 2- or 3-wire connection<br />

0 V +24 V<br />

9 10<br />

L<br />

H<br />

• Automatic cable-length compensation<br />

2 A<br />

3 B<br />

4<br />

BSENSE<br />

J<br />

PS<br />

Ch 1<br />

Ch 2<br />

11<br />

12<br />

13<br />

14<br />

15<br />

16<br />

Technical data<br />

Connections<br />

F<br />

Input<br />

Type<br />

Sensor current<br />

Output digital<br />

Type<br />

Number of channels<br />

Switching current<br />

Settings<br />

Fine adjustment<br />

Hysteresis<br />

Range of adjustment<br />

General data<br />

Cable-length compensation<br />

PT100 2-/3-wire<br />

0.5 mA<br />

Relay output, change-over contact<br />

2<br />

3 A @ 240 V AC, 3 A @ 24 V DC / 110 V AC<br />

Potentiometer, 20 turns<br />

1...25 % of max. input value<br />

0 - 100 % of max. input value<br />

The cable-length compensation reduces the influence of con-<br />

Terminal <strong>Signal</strong><br />

1 Unassigned<br />

2 A<br />

3 B<br />

4 B-Sense<br />

Supply voltage<br />

Power consumption<br />

Repeat accuracy<br />

Long-term drift<br />

Humidity<br />

Temperature coefficient<br />

Step response time<br />

Ambient temperature / Storage temperature<br />

Approvals<br />

Insulation coordination<br />

Impulse withstand voltage<br />

Insulation voltage<br />

EMC standards<br />

ductor resistances by a factor of 100.<br />

24 V DC ± 10 %<br />

3 W @ 24 V DC<br />

± 0.05 % of signal range<br />

0.1 % / 10.000 h<br />

0 to 90 % (no condensation)<br />

< 0.04 % / °C<br />

typ. 5 ms<br />

0 °C...+60 °C / -25 °C...+70 °C<br />

cULus; CE<br />

4 kV (1.2/50 µs)<br />

2 kV input / output / power supply<br />

DIN EN 61326<br />

Dimensions<br />

Clamping range (nominal / min. / max.)<br />

Length x width x height<br />

Note<br />

mm²<br />

mm<br />

Screw connection<br />

1.5 / 0.5 / 2.5<br />

120 / 46 / 97<br />

PE connection direct on enclosure<br />

Ordering data<br />

Connection system<br />

Note<br />

Temperature signal converters<br />

Temperature signal converters<br />

Temperature signal converters<br />

Type Qty. Order No.<br />

DPARTD 0-100C 1 7940014900<br />

DPARTD 0-200C 1 7940017852<br />

DPARTD 0-50C 1 7940014212<br />

Accessories<br />

F.30