Intrinsically safe signal conditioners<br />

for hazardous area applications<br />

ACT20X<br />

NAMUR isolating switching amplifier: with relay output<br />

The ACT20X-HDI-SDO-RNO (NC) isolating switching amplifier is a specialized signal<br />

isolating converter for Namur sensor signals or for simple switching signals from the<br />

Ex Zone 0. A single relay, available optionally as NC or NO, provides the output signal<br />

in the safe zone. Single-channel or double-channel versions are also available.<br />

B<br />

Connection diagram: ACT20X HDI-SDO-RNC<br />

Ex label<br />

Channel 1:<br />

Input <strong>Signal</strong>s<br />

NAMUR<br />

+<br />

Mechanical<br />

switch<br />

– R p<br />

R s<br />

R p<br />

14<br />

13<br />

12<br />

11<br />

44<br />

43<br />

42<br />

41<br />

Output <strong>Signal</strong>s<br />

Relay<br />

Relay<br />

Relay<br />

Relay<br />

Channel 2:<br />

N.O. or N.C.<br />

Channel 1:<br />

N.O. or N.C.<br />

ATEX<br />

II 3 G Ex nA nC IIC T4<br />

II (1) G [Ex ia] IIC/IIB/IIA<br />

II (1) D [Ex iaD]<br />

IECEx<br />

Ex nA nC IIC T4 Gc<br />

[Ex ia Ga] IIC/IIB/IIA<br />

[Ex ia Da] IIIC<br />

FM<br />

Installation in CL I DIV2 GP A-D T4<br />

Protects Ex circuits, in compliance with<br />

Cl. I-III ABT 1/2 GP A-G or<br />

Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.<br />

Channel 2:<br />

NAMUR<br />

+<br />

Mechanical<br />

switch<br />

– R p<br />

R s<br />

R p<br />

24<br />

23<br />

22<br />

Power Supply<br />

Gnd. –<br />

51<br />

Supply +19.2...31.2 V DC<br />

52<br />

Module status<br />

53<br />

N.C.<br />

21<br />

54<br />

Module status<br />

Zone 0, 1, 2, 20, 21, 22 /<br />

Cl. I/II/III, div. 1 gr. A-G<br />

Zone 2 / FM Cl. 1,<br />

div. 2, gr. A-D o safe area<br />

Note<br />

Application: monitoring of fill level with the ACT20X HDI-SDO-RNO<br />

(relay output)<br />

EX Zone<br />

Safe zone<br />

A.C. supply<br />

Control<br />

+24 V DC<br />

+<br />

Power<br />

supply<br />

Fill level is high,<br />

intrinsically safe Namur<br />

or mechanical switch<br />

PS<br />

0 V<br />

-<br />

Other converter<br />

Channel 1 digital input<br />

Channel 1 digital output<br />

Zone 0<br />

Channel 2 digital input<br />

Channel 2 digital output<br />

ACT20X-2HDI-2SDO-RNO<br />

Tank<br />

Fill level is low,<br />

intrinsically safe Namur<br />

or mechanical switch<br />

B.6