<strong>System</strong> environment A basics<br />

<strong>System</strong> <strong>description</strong><br />

Module <strong>description</strong>s<br />

1.1<br />

<strong>System</strong> Module ][Bezeichnungen environment <strong>description</strong>s<br />

Sys Abasics<br />

The module <strong>description</strong>s provide information<br />

on their function. The <strong>description</strong>s<br />

are made up of multi-level<br />

combinations of letters and numbers.<br />

All module names begin with PSSu.<br />

This is followed by:<br />

H for head modules<br />

e. g.: PSSu H SB DP<br />

E for electronic modules, followed<br />

by:<br />

– S for standard module,<br />

e.g.: PSSu E S 4DI<br />

– F for failsafe module,<br />

e.g.: PSSu E F 4DI<br />

K for compact modules, followed<br />

by:<br />

– S for standard module,<br />

e.g.: PSSu K S 16DI<br />

– F for failsafe module,<br />

e.g.: PSSu K F 16DI<br />

B for base modules,<br />

e.g.: PSSu BP 1/8S<br />

1.1<br />

Base modules Basic function Size <strong>Co</strong>nnection type Additional function<br />

PSSu B... PSSu BP... – Base module<br />

for periphery (input/output)<br />

PSSu BP-C… – Base module<br />

for periphery with C-rail<br />

PSSu BS... – Base module<br />

for power supply<br />

PSSu BS-R... – Base module<br />

for refreshing the power<br />

supply<br />

PSSu BP-C 1/8... – 1 x<br />

grid width, 8 connections<br />

PSSu BP-C 1/12... – 1 x<br />

grid width, 12 connections<br />

PSSu BP-C 2/16… – 2 x<br />

grid width, 16 connections<br />

PSSu BP-C 2/8... – 2 x<br />

grid width, 8 connections<br />

PSSu BP-C 1/8C – Cage<br />

clamp terminals<br />

PSSu BP-C 1/8S – Screw<br />

terminals<br />

PSSu BP 1/8S-J –<br />

Integrated cold junction<br />

compensation<br />

Link modules have individual letter<br />

codes, depending on their application,<br />

e. g.:<br />

PSSu WB S IDN, PSSu WR S IDN<br />

(for wireless communication with<br />

InduraNET p)<br />

PSSu XB F-T, PSSu XR F-T<br />

(for cable-based subdivision)<br />

The accessories of the PSSu systems<br />

are designated PSSu A... .<br />

PSSu modules are available which are<br />

suitable for use in applications with increased<br />

environmental requirements<br />

on temperature and humidity. These<br />

are called coated versions of PSSu<br />

modules. The functionality of the coated<br />

versions of PSSu modules is no different<br />

from that of uncoated modules.<br />

They are identified by a "-T" at the end<br />

of the product name, e.g.:<br />

PSSu E F DI OZ 2-T.<br />

<strong>System</strong> Module ][Bezeichnungen environment <strong>description</strong>s<br />

Zusatz A basics TK/<strong>System</strong>beschr. PSSu Sys A + B<br />

In the following text, the designation<br />

"PSSu E F DI OZ 2(-T)", with "-T" in<br />

brackets, is used when the information<br />

specifically refers to both modules. In<br />

function <strong>description</strong>s and diagrams,<br />

"PSSu E F DI OZ 2" is used to represent<br />

both modules.<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

2011-04<br />

1.1-7