Modules<br />

Head modules<br />

PSSu H PLC1 FS DP SN SD<br />

Module features<br />

Module <strong>description</strong><br />

3.2<br />

3.2 PSSu-2011-01<br />

Modules Head Gertebild modules<br />

H PLC1 FS DP SN SD<br />

][Bildunterschrift SN<br />

Head module to connect the "<strong>Co</strong>ntrol<br />

system PSSu PLC" to SafetyNET p.<br />

Approvals<br />

Zulassungen<br />

Unit not shown<br />

SÜDDEUTSCHLAND<br />

PSSu H PLC1 FS DP<br />

SN SD<br />

<br />

<br />

<br />

][Merkmale_Zusatz BA Einleitung PLC<br />

The head module belongs to the performance<br />

class "<strong>Co</strong>ntrol system<br />

PSSu PLC". It can be used to connect<br />

a PSSu system to SafetyNET p. The<br />

head module has the following features:<br />

][Merkmale_1_Schnittstellen SN<br />

1 free switch ports for connection to<br />

SafetyNET p<br />

Merkmal PROFIBUS DP interface<br />

][Merkmale_PLC<br />

One FS resource and one ST resource<br />

SD card used to store the device<br />

project and the naming data<br />

Reset button<br />

– For warm reset<br />

– To transfer the naming data and/<br />

or device project from the SD<br />

card to the device memory<br />

][Merkmale_Versorgung Kopf<br />

Supply voltage<br />

– Integrated supply voltage for periphery<br />

supply and module supply<br />

– Infeed for C-rail supply<br />

– Module supply is buffered for<br />

20 ms if the supply voltage is interrupted<br />

– Plug-in connection terminals (either<br />

spring-loaded terminal or<br />

screw terminal)<br />

][Merkmale_LED SN<br />

Status LEDs<br />

][Merkmale_E-Module Kopf<br />

Supports FS and ST modules<br />

][Bestimmung SN und DP<br />

The module is designed for use in:<br />

Safety-related applications with<br />

– SafetyNET p<br />

– PROFIBUS DP with local enable<br />

principle<br />

Non-safety-related applications<br />

with<br />

– PROFIBUS DP<br />

– SafetyNET p<br />

Integrated protection mechanisms<br />

][Schutzmechanismen H SN und DP<br />

The module has the following protection<br />

mechanisms:<br />

Multi-channel diverse processor<br />

section<br />

Cyclical self tests<br />

Potentially isolated SafetyNET p<br />

interface<br />

Potentially isolated PROFIBUS DP<br />

interface<br />

Infeed for module supply<br />

– Polarity protection<br />

– Voltage monitoring<br />

– Transient voltage limitation<br />

– 20 ms voltage buffer if the supply<br />

voltage is interrupted<br />

Module supply<br />

– Short circuit-proof<br />

Periphery supply<br />

– Voltage monitoring (exceeding<br />

upper/lower limit)<br />

Block diagram<br />

Blockschaltbild<br />

Module Bus<br />

Module<br />

Supply<br />

+ 5 V DC<br />

Data<br />

(FS/ST)<br />

SafetyNET p<br />

PROFIBUS DP SD Card<br />

24V 0V C 24V 0V<br />

Periphery<br />

=<br />

Supply<br />

+ 24 V DC<br />

=<br />

Power<br />

Periphery<br />

Supply<br />

Power<br />

Module<br />

Supply<br />

5<br />

9<br />

6<br />

1<br />

Data<br />

(ST)<br />

<strong>Co</strong>nfig./<br />

Data<br />

(FS/ST)<br />

<strong>Co</strong>nfiguration<br />

3.2-74<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

PSSu-2011-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!