Modules<br />

Digital input/output (standard)<br />

PSSu E S 4DI-D<br />

Module features<br />

Module <strong>description</strong><br />

3.4<br />

3.4 PSSu-2011-01<br />

Modules Digital Gertebild<br />

E input/output S 4DI-D (standard)<br />

][Bildunterschrift ST-Eingang digital Diag<br />

Electronic module with digital inputs<br />

and expanded diagnostics for standard<br />

applications.<br />

Zulassungen<br />

][Merkmale_Ein_Aus ST-Eingang<br />

4 Digital inputs<br />

][Merkmale_Ausgänge PD-D/4DI-D<br />

2 Outputs for periphery supply:<br />

– Current load capacity per output:<br />

0.25 A<br />

– Short circuit-proof<br />

– Overload-proof<br />

][Merkmale_LED Eingang<br />

LEDs for:<br />

– Switch status of each input<br />

– Module error<br />

][Merkmale_Zusatz ST-Module Sys A<br />

For standard applications in system<br />

environment A<br />

][Merkmale_Zusatz ST-Module<br />

<strong>Co</strong>mmunication via:<br />

– Standard fieldbus<br />

][Merkmale_Zusatz Diag<br />

The module provides advanced diagnostic<br />

data.<br />

][Gertebeschreibung ST-Eingang<br />

The module provides type 1 inputs in<br />

accordance with IEC 61131-2. It may<br />

be used as an input module for standard<br />

functions.<br />

][Gertebeschreibung ST-Module Sys A<br />

The module may be used for standard<br />

applications in system environment A.<br />

Integrated protection mechanisms<br />

][Schutzmechanismen E/A-Module<br />

When the PSSu E F PS1(-T) is used to<br />

supply the system, the module supply<br />

is buffered for 20 ms if the supply voltage<br />

is interrupted.<br />

][Schutzmechanismen ST-Module Diag<br />

The module provides the following diagnostic<br />

data:<br />

Start-up error<br />

<strong>Co</strong>nfiguration error<br />

ST communication error<br />

Bus termination error<br />

Output overload<br />

Temperature error: too warm<br />

Temperature error: too hot<br />

Block diagram<br />

Blockschaltbild<br />

11 21 14 24<br />

Module Bus<br />

Periphery<br />

Supply<br />

+ 24 V DC<br />

Module<br />

Supply<br />

+ 5 V DC<br />

Input Input Input Input<br />

Data<br />

(ST)<br />

12 22 13 23<br />

3.4-8<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

PSSu-2011-01