03.04.2015 Views

System description - Pilz GmbH & Co.

System description - Pilz GmbH & Co.

System description - Pilz GmbH & Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Modules<br />

Digital input/output (failsafe)<br />

PSSu E F 2DOR 8(-T)<br />

Service life graph<br />

Lebensdauerkurve_Relais_Text vor Kurve<br />

The service life graphs indicate the<br />

number of cycles from which failures<br />

due to wear must be expected. The<br />

wear is mainly caused by the electrical<br />

load; the mechanical load is negligible.<br />

D Nennbetriebstrom (A)<br />

GB Nominal operating current (A)<br />

F <strong>Co</strong>urant coupé (A)<br />

E <strong>Co</strong>rriente nominal de servicio (A)<br />

I <strong>Co</strong>rrente di esercizio nominale (A)<br />

NL Nominale bedrijfsstroom (A)<br />

10<br />

1<br />

AC15: 230 V<br />

DC13: 24 V<br />

Lebensdauerkurve<br />

AC1: 230 V<br />

DC1: 24 V<br />

0.1<br />

10 100 1000 10000<br />

D Schaltspielzahl x 10 3<br />

E Número de ciclos x 10 3<br />

F Nombre de manœvres x 10 3 NL Aantal schakelingen x 10 3<br />

GB Cycles x 10 3<br />

I Numero dei cicli di commutazione x 10 3<br />

Lebensdauerkurve_Relais_Text nach Kurve_SIS212_SIR-SLR Bsp<br />

Example<br />

Inductive load: 0.2 A<br />

Utilisation category: AC15<br />

<strong>Co</strong>ntact service life: 1 000 000 cycles<br />

Provided the application requires fewer<br />

than 1 000 000 cycles, the PFH value<br />

(see technical details) can be used<br />

in the calculation.<br />

To increase the service life, sufficient<br />

spark suppression must be provided<br />

on all output contacts. With capacitive<br />

loads, any power surges that occur<br />

must be noted. With contactors, use<br />

freewheel diodes for spark suppression.<br />

Lebensdauerkurve_Relais_Text nach Kurve-2_ Empfehlung sichere Halbleiterausgänge<br />

We recommend you use semiconductor<br />

outputs to switch 24 VDC loads.<br />

][Technische Daten PSSu Digitale E/A/K<br />

3.5<br />

Technical details<br />

Application range<br />

Failsafe<br />

Maximum achievable category in accordance with EN 954-1 4<br />

Maximum achievable SIL value<br />

SIL3<br />

Module's device code<br />

0C03h<br />

Number of FS output bits 2<br />

Support in system environment A<br />

from FS firmware version for other head modules 4<br />

from FS firmware version PSSu H F PN 1<br />

Support in system environment B<br />

from head module FS firmware version 1.0.0<br />

Electrical data<br />

Internal supply voltage (module supply)<br />

Supply voltage range of module supply<br />

4.8 - 5.4 V<br />

Module's current consumption<br />

40 mA<br />

Module's power consumption<br />

0.20 W<br />

Periphery's supply voltage (periphery supply)<br />

Voltage range<br />

16.8 - 30.0 V<br />

Module's current consumption with no load<br />

60 mA<br />

Module's power consumption with no load<br />

1.50 W<br />

Max. power dissipation of the module<br />

2.50 W<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

PSSu-2011-01<br />

3.5-33