03.04.2015 Views

System description - Pilz GmbH & Co.

System description - Pilz GmbH & Co.

System description - Pilz GmbH & Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Modules<br />

Voltage supply<br />

PSSu E F PS1(-T)<br />

3.3<br />

3.3 PSSu-2011-01<br />

Modules Voltage Gertebild<br />

E supply<br />

F PS1(-T)<br />

][Bildunterschrift PS<br />

Electronic module to provide the<br />

PSSuniversal system with the module<br />

supply, periphery supply and C-rail<br />

supply<br />

Approvals<br />

SÜDDEUTSCHLAND<br />

PSSu E F PS1<br />

<br />

<br />

<br />

Module features<br />

][Merkmale_Versorgung PS1<br />

Power supply for max. 2.0 A<br />

When the supply voltage is interrupted,<br />

the module supply is buffered<br />

for 20 ms.<br />

Separate infeed for periphery supply<br />

Separate infeed for module supply<br />

Infeed for C-rail supply<br />

][Merkmale_LED PS<br />

LEDs for:<br />

– Module supply<br />

– Periphery supply<br />

– Module error<br />

][Merkmale_Zusatz<br />

Application range depends on the<br />

base module<br />

][Geraetemerkmal_T<br />

<strong>Co</strong>ated version of the module:<br />

PSSu E F PS1-T: for increased environmental<br />

requirements<br />

Module <strong>description</strong><br />

][Gertebeschreibung PS<br />

The module provides the supply for<br />

the module supply and periphery supply<br />

within the system.<br />

Depending on which base module is<br />

used, the module may be used as a:<br />

General supply module (first module<br />

after a head module, if the head<br />

module does not have an integrated<br />

supply voltage)<br />

Supply module to refresh the module<br />

supply and periphery supply<br />

Supply module to form supply<br />

groups<br />

The module PSSu E F PS1-T is suitable<br />

for use where there are increased<br />

environmental requirements (see<br />

Technical Details).<br />

Integrated protection mechanisms<br />

][Schutzmechanismen PS<br />

The module has the following protection<br />

mechanisms:<br />

Infeed for module supply<br />

– Polarity protection<br />

– Voltage monitoring<br />

– Transient voltage limitation<br />

Module supply<br />

– Short circuit-proof<br />

Periphery supply<br />

– Voltage monitoring (exceeding<br />

upper/lower limit)<br />

The module registers the following errors:<br />

Start-up error<br />

<strong>Co</strong>nfiguration error<br />

FS communication error<br />

Bus termination error<br />

Temperature error: too warm<br />

Overvoltage error<br />

Undervoltage error<br />

Error in the overvoltage protection<br />

diodes<br />

Zulassungen<br />

Bestimm_Verwend_Zusatz-(T)<br />

Block diagram<br />

Blockschaltbild<br />

12 22 13 23<br />

11 21<br />

Module Bus<br />

Periphery<br />

Supply<br />

+ 24 V DC<br />

Module<br />

Supply<br />

+ 5 V DC<br />

Power<br />

=<br />

=<br />

Power<br />

Data<br />

(FS)<br />

Periphery<br />

Supply<br />

Module<br />

Supply<br />

(C-Rail)<br />

14 24<br />

3.3-12<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />

Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: pilz.gmbh@pilz.de<br />

PSSu-2011-01

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!