Modules<br />

Digital input/output (standard)<br />

PSSu E S 2DOR 10(-T)<br />

3.4<br />

3.4 PSSu-2011-01<br />

Modules Digital Gertebild E input/output S 2DOR 10(-T) (standard)<br />

][Bildunterschrift ST-Ausgang Relais<br />

Electronic module with relay outputs<br />

for standard applications<br />

Approvals<br />

Zulassungen<br />

PSSu E S 2DOR 10<br />

<br />

Module features<br />

][Merkmale_Ein_Aus Ausgang Relais ST<br />

2 relay contacts<br />

– Normally open contact<br />

– Volt-free<br />

– Current load capacity per output:<br />

10.0 A<br />

][Merkmale_LED Ausgang<br />

LEDs for:<br />

– Switch status of each output<br />

– Module error<br />

][Merkmale_Zusatz ST-Module Sys A<br />

For standard applications in system<br />

environment A<br />

][Geraetemerkmal_T<br />

<strong>Co</strong>ated version of the module:<br />

PSSu E S 2DOR 10-T: for increased<br />

environmental requirements<br />

][Merkmale_Zusatz ST-Module<br />

<strong>Co</strong>mmunication via:<br />

– Standard fieldbus<br />

Module <strong>description</strong><br />

][Gertebeschreibung ST-Ausgang Relais<br />

The module provides type 1 relay<br />

ouputs in accordance with IEC 61131-<br />

2. It may be used to switch:<br />

Resistive loads<br />

Inductive loads<br />

][Gertebeschreibung ST-Module Sys A<br />

The module may be used for standard<br />

applications in system environment A.<br />

Bestimm_Verwend_Zusatz-(T)<br />

The module PSSu E S 2DOR 10-T is<br />

suitable for use where there are increased<br />

environmental requirements<br />

(see Technical Details).<br />

][DB Bestimmung Ausschluss ST Relais<br />

The module may not be used in combination<br />

with PSSu E F BSW(-T) modules<br />

in safety-related applications.<br />

Integrated protection mechanisms<br />

][Schutzmechanismen E/A-Module<br />

When the PSSu E F PS1(-T) is used to<br />

supply the system, the module supply<br />

is buffered for 20 ms if the supply voltage<br />

is interrupted.<br />

][Schutzmechanismen ST-Ausgang Relais<br />

The module has the following protection<br />

mechanisms:<br />

Safe separation between both relay<br />

contacts (see Technical details)<br />

Safe separation between both relay<br />

contacts and the periphery supply<br />

as well as the module supply, in accordance<br />

with DIN VDE 0110 overvoltage<br />

category 2 in a protected<br />

industrial network<br />

Temperature monitoring<br />

The module provides the following diagnostic<br />

data:<br />

Start-up error<br />

<strong>Co</strong>nfiguration error<br />

ST communication error<br />

Bus termination error<br />

Temperature error: too warm<br />

Temperature error: too hot<br />

Block diagram<br />

Blockschaltbild<br />

12 22<br />

32 42 31 41 34 44<br />

11 14<br />

Module Bus<br />

Periphery<br />

Supply<br />

+ 24 V DC<br />

Module<br />

Supply<br />

+ 5 V DC<br />

Data<br />

(ST)<br />

K0<br />

K1<br />

(C-Rail)<br />

13 23 33 43<br />

21 24<br />

3.4-48<br />

<strong>Pilz</strong> <strong>GmbH</strong> & <strong>Co</strong>. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany<br />