CHAPTER 7 • DATA SETUP AND COLLECTION 79NoteSome of the settings discussed in this chapter can affect the storage capacity ofyour sensor. Changing such data collection settings as the length of the interval forcollecting interval data and the number of bins and approaches configured will affecthow many reports your sensor can store onboard (see Table 7.1 for examples). Alwayscheck back to the Storage Status screen after you have changed all other settings toget the most accurate information on how often your sensor will need to have informationon how often your sensor will need to have information downloaded from it.IntervalLanes &ApproachesClass Bins Speed Bins Onboard StorageCapacity20 sec 4 4 0 17 days20 sec 12 4 0 6 days20 sec 12 4 10 3 days15 min 4 4 0 25 months 29 days15 min 12 4 0 9 months 26 days15 min 12 4 10 5 months 3 days1 hour 4 4 0 103 months 29 days1 hour 12 4 0 39 months 15 days1 hour 12 4 10 20 months 13 daysTable 7.1 – Examples of Onboard Storage Time Based upon Configuration3. Data DownloadThe Data Download window allows you to specify the time for which stored data will retrievedand the location where it will be saved to file (see Figure 7.8).