Boiler Manual - Weil-McLain

Boiler Manual - Weil-McLain

Boiler Manual - Weil-McLain

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

GV90+ gas-fired water boiler — <strong>Boiler</strong> <strong>Manual</strong>Venting & air — general (cont.)Figure 40 Vent and air piping materials — Use only the materials listed below, ensuring that all materials meetlocal codesItemMaterialPVC schedule 40Standards for installations in:United StatesCanadaPlastic piping materialsANSI/ASTM D1785Vent or air pipe&fittingsPVC-DWV (Note 1)CPVC schedule 40 (Note 1)ABS-DWV schedule 40 (Note 1)PVCANSI/ASTM D2665ANSI/ASTM F441ANSI/ASTM D2661ANSI/ASTM D2564 & F656Plastic vent pipe must be certified toULC S636 when required. (Note 2)Air pipe can be any of those listed atleft if acceptable for local codes.PVC & ABS pipecement & primerCPVC (Note 1)ANSI/ASTM F493ABS (Note 1)ANSI/ASTM D2235AL29-4C piping materialsVent pipeAL29-4CstainlesssteelHeat Fab, Inc. — Saf-T-Vent ®Z-Flex, Inc. — Z-Vent IIDura-Vent — FasNSealMetal-Fab, Inc. — CORR/GUARDCertified for Category IV and direct ventappliance venting—<strong>Weil</strong>-<strong>McLain</strong> bird screens (purchase separately)<strong>Weil</strong>-<strong>McLain</strong>bird screens3” vent screen:W-M part number 383-500-105Note 1: DO NOT use DWV, CPVC or ABS when using concentric vent termination. Use ONLY PVC schedule 40.Note 2:IPEX PVC concentric terminations utilize PVC pipe/fittings certified to ULC S636. Where ULC S636 compliance is required, useonly IPEX System 636 pipe, fittings and cement.AL29-4C vent piping — Install a PVC-to-stainless adapter supplied by the vent pipe manufacturer at the boiler vent connectionand at the termination (when using <strong>Weil</strong>-<strong>McLain</strong> plate or concentric PVC termination). DO NOT mix piping from different ventpipe manufacturers unless using adapters specifically designed for the purpose by the manufacturer.Plastic piping — Do not attempt to connect different types of plastic piping together.DO NOT use cellular core pipe.All vent and air pipes require a bird screen at each termination. Most kits do notinclude the bird screens. Purchase bird screens separately from <strong>Weil</strong>-<strong>McLain</strong> or vent kitsupplier if not included. [Note — bird screening is integral to the <strong>Weil</strong>-<strong>McLain</strong> sidewall ventcap, supplied standard with all GV90+ boilers. No additional screening is required.]Part number 550-142-054/1211 33

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!