GV90+ gas-fired water boiler — <strong>Boiler</strong> <strong>Manual</strong>Troubleshooting (continued)IgniterWait several minutes until igniter cools down before attemptingreplacement. Failure to do so will cause severepersonal injury.1. Disconnect igniter (Figure 86) from igniter wiring harness andremove igniter before removing from blower assembly.2. Replace igniter gasket if original gasket is frayed or damaged ORif room-temperature resistance across igniter is not between 40and 95 ohms.3. Igniter is fragile — handle with care. Do not touch igniter surfacewith bare hands. Body oils can cause failure of the carbide.Figure 86 IgniterFigure 87 Gas valveGas ValveThe gas valve (Figure 87) operates with a negative pressureat the outlet — approximately –0.2” w.c. — DONOT set gas pressure higher than this.Follow instructions in this manual carefully if testinggas valve outlet pressure. Failure to comply can result insevere personal injury or death.The gas valve outlet is bolted to the gas line adapter andsealed with an o-ring. When replacing valve, replace onlywith valve listed in this manual for use with the GV90+boiler. Failure to comply could result in severe personalinjury, death or substantial property damage.Figure 88 Blower housingBlower HousingDo not disassemble blower housing (Figure 88). Afire or explosion causing severe personal injury, death orsubstantial property damage can result. If you suspect aproblem, replace blower housing. Follow instructions onpage 72 for blower housing removal and replacement.Thermal fuse1. The thermal fuse (Figure 89) protects vent pipe from excess fluetemperatures.2. If the thermal fuse opens, it must be replaced. See page 94 forreplacement information.If the thermal fuse opens, investigate the cause beforereplacing switch and starting the boiler. DO NOT attemptto jumper the switch. Failure to comply could result insevere personal injury, death or substantial propertydamage.Figure 89 Thermal fuseFigure 90 Return temperature sensorReturn temperature sensor1. See Figure 90.2. Resistance check method:a. With the boiler operating, use a contact thermometer tomeasure the temperature of the return pipe next to the returntemperature sensor. Make a note of the temperature.b. Turn the boiler ON/OFF switch off.76Part number 550-142-054/1211

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!