GV90+ gas-fired water boiler — <strong>Boiler</strong> <strong>Manual</strong>Service & maintenance (continued)To clean the burnerThe burner may contain ceramic fiber particles. Usecare when handling these materials per instructions onpage 107 of this manual. Failure to comply could resultin severe personal injury.1. Clean the burner ports with a soft brush.2. Use compressed air to blow out any particulate if necessary. Usecaution to avoid particulate being blown into the building.To replace blower assembly1. Place a new blower flange gasket over the studs at combustionchamber opening.2. Reinstall burner cone into chamber opening.3. Position blower assembly over studs. Install nuts and tighten.4. Install igniter and new igniter gasket. Fasten with screws and washers.Tighten only with hand-held screwdriver. DO NOT use electricor pneumatic driver. Excessive torque will damage igniter. Do notexceed 20 inch-pounds torque.5. Connect:a. Gas valve and piping (4 screws)b. Gas tubing to gas valve outletc. Pressure switch hosesd. Hose from gas valve to gas/air manifolde. Air inlet hosef. Blower motor wiring harness to IBCg. Igniter harness to igniter plugh. Blower support bracket (with screw)i. Ground wire.6. Be sure all wiring and hose connections are correct per Figure81, page 72and are secure on the hose barb fittings.Figure 82 Recuperator access and cleaningFigure 83 Recuperator with access panel removed(GV90+3/4 top, GV90+5/6 bottom)Inspecting and cleaning the recuperatorTurn off power and gas to the boiler. Failure to do socan cause severe personal injury, death or substantialproperty damage.Wait several minutes after boiler has stopped to allowthe boiler components to cool to avoid severe personalinjury or death.1. Remove the recuperator access panel and gasket (see Figure 82)and inspect the interior with a flashlight.2. If there are indications of debris or corrosion, disconnect thecondensate trap from the bottom of the recuperator and place acatch pan underneath.3. Flush the flueway (Figure 83, item 1) and tubes (Figure 83, item 2)thoroughly with fresh water, allowing the water to drain outthrough the recuperator condensate opening.4. If all of the water doesn't drain from the flueway (Figure 83,item 1), the drain holes (see Figure 84) may be plugged. Removethe recuperator using the procedure under Removing/cleaning/re-installing the recuperator, page 74.Part number 550-142-054/1211 73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!