Sening®<br />

Innovative Tank Truck Systems<br />

3.6.3 Control of Discharges<br />

MultiFlow Product guidelines - PRESETs:<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,METER,SETUP,MeterCount<br />

OBC <br />

OBC REPORT,METER,SETUP,METERCOUNT=“2“ // tank truck with 2 MultiFlows<br />

<strong>EMIS</strong> <br />

<strong>EMIS</strong> REQUEST,METER,STATUS(0) // status request for 1.MutiFlow<br />

OBC <br />

OBC REPORT,METER,STATUS(0),LASTERROR=“0000:No Error“;MODE=“READY“…<br />

<strong>EMIS</strong> <br />

<strong>EMIS</strong> SET,METER,ORDERS,ReInit =“123“ // initiate the discharge sequence<br />

OBC <br />

<strong>EMIS</strong> SET,METER, ORDERS,PRESET(0),PCode=1;Volume=1000;PUnit=”L”<br />

OBC <br />

<strong>EMIS</strong> SET,METER, ORDERS,PRESET(1),PCode=2;Volume=200;PUnit=”L”<br />

OBC <br />

<strong>EMIS</strong> SET,METERS,ORERS,OrderCount=2 // presets complete<br />

OBC <br />

OBC REPORT,METERS,ORERS,ORDERCOUNT=“2“ // presets tranmitted<br />

<strong>EMIS</strong> <br />

Initiation of the discharge sequence begins when METERS,ORDERS,Count is<br />

successfully set to the count of the valid orders, it the status of the measuring<br />

system(s) is "Ready". Compare this with Chapter 3.4 / page 15.<br />

Particular note should be taken of the fact that in the above example no particular measuring<br />

system is named when the discharge presets are transferred. The interface (gateway) is<br />

responsible for distributing the data to the available measuring systems.<br />

This mechanism means that an OBC can communicate with the measuring system(s) even without<br />

any detailed knowledge of the device configuration.<br />

MultiFlow <strong>Measurement</strong> - RESULTs:<br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,METER,ORDERS,RESULT(0)<br />

OBC <br />

OBC<br />

REPORT,METER,ORDERS,RESULT(0),PCODE=”001”;VOLUME=” 998”;<br />

PUNIT=”L”;METERID=”18DC-80363 “; … CHECK=“OK“<br />

<strong>EMIS</strong> <br />

<strong>EMIS</strong> REQUEST,METER,ORDERS,RESULT(1)<br />

OBC <br />

OBC<br />

REPORT,METER,ORDERS,RESULT(1),PCODE=”002”;VOLUME=” 234”;<br />

PUNIT=”L”;METERID=”18DC-80363 ”; … CHECK=“OK“<br />

<strong>EMIS</strong> <br />

Check = "Ok" indicates a correct and complete "Result Telegram".<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 19<br />