Sening ®<br />

Innovative Tank Truck Systems<br />

Appendix A<br />

E7 Protocol – TDL formated data<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

As an alternative to the “DOK-411 Communcation“, there is the additional possibility since the<br />

emergence of the <strong>EMIS</strong> software version 3.12 to recall some information in the TDL format (see<br />

DIN 26051-1 and DIN 26051-2). The protocol used here varies slightly from the one described<br />

above. Communicatioin is done in keeping with the E7 specification. This involves a protocol<br />

oriented to the DOK-411 format which 7 leading European manufacturers commercially involved<br />

with communication on the tank truck have agreed to. The E7 specification is available as a<br />

separate doument.<br />

Definitions are provided for several sub-nodes in a further "TDL" designated node. The <strong>EMIS</strong><br />

currently supports the L_FILE, SYSTEM, GPS, PRN and AUX sub-nodes.<br />

TDL,L_FILE<br />

In a similar manner to QAS,EVENT, the TDL,L_FILE node can recall setup and event information.<br />

Given that basically no other data is available, the TDL formatted output solely represents data<br />

conversion from the setup or event table (see Chapters 4.2.1.2 and 4.2.1.3).<br />

The entry in the setup table (TDL Identifier 800 Field index) specifies the index of the individual<br />

setup information in the TDL string (see Setup information TDL Identifier 800).<br />

Example from the setup table:<br />

Setup description TYPE VALUE1 VALUE2<br />

TDL<br />

Identifier<br />

800<br />

Field index<br />

Number of output drivers SET02 IO 0 to 4 e.g. 2 4<br />

REPORT,TDL,L_FILE=800,20060106143800,11,FAS,2,0,0, …..<br />

In the event table (4.2.1.3 / Page 33) conversion into the TDL format is listed in the line below.<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 73<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

A<br />

Anhang A Protokolle