Event / sensor TYPE VALUE1 VALUE2<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
TDL 45,S, ,V1, , ,4 / 45,S, ,V1, , ,4, ,V2[4]V2[5], , ,V2[0]V2[1],V2[2]V2[3]<br />
“0“ = end of loading<br />
Uncoded loading UCL CoNo<br />
or<br />
PrCo at start of loading<br />
TDL 41,S,V1, ,1, , , ,1 / 41,S,V1,V2,1, , , ,1 3)<br />
Valve driver digital<br />
input<br />
1 in [8] bezeichnet uncodierte Beladung<br />
VDI<br />
“n“ = Input no.<br />
“1“ = External setup -<br />
key switch<br />
“2“ = External ANA<br />
TDL 820,S,NoID,FAS,V1,V2 4)<br />
Solenoid valve VEN Valve number<br />
TDL 43,S,0,19,(1) (2) >> V2[..],V1<br />
Vapour recovery<br />
overpressure<br />
sensor<br />
VEP<br />
“0“ = NO overpressure<br />
“1“ = overpressure<br />
TDL 42,S, ,21,(2) (1) >> V1[..]<br />
Vapour recovery<br />
underpressure<br />
sensor<br />
VNP<br />
“0“ = NO underpressure<br />
“1“ = underpressure<br />
TDL 42,S, ,22,(2) (1) >> V1[..]<br />
Vapour recovery<br />
hose monitor<br />
VRC<br />
Vapour recovery coupling<br />
“1“ = GPS-connection no. 1<br />
“2“ = GPS-connection no. 2<br />
“3“ = GPS-connection no. 3<br />
“4“ = GPS-connection no. 4<br />
“5“ = collective GPS<br />
connection<br />
TDL 42,S, ,5,(2) (1) >> V2[..],V1<br />
Wetleg Digital Input WDI<br />
“n“ = Input no.<br />
“1“ = compressed air sensor<br />
“2“ = GPSÜ (vapour recovery<br />
hose overpressure)<br />
TDL 821,S,NoID,FAS,V1,V2 4)<br />
Water detection<br />
(sensor status)<br />
WTR CoNo<br />
TDL 826,S,NoID,FAS,V1,V2 4)<br />
“0“ = passive<br />
“1“ = active<br />
“0“ = switched off (closed)<br />
“1“ = switched on (open)<br />
Connection status<br />
“0“ = interrupted<br />
“1“ = connected<br />
“0“ = pressure low / passive<br />
“1“ = pressure high / active<br />
“0“ = passive<br />
“1“ = active (water in compartment)<br />
“2“ = not connected<br />
“3“ = short-circuit<br />
“4“ = invalid / unknown<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 37<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Variablendefinition