Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
If printer is assigned to OBC:<br />
Direction Telegram<br />
<strong>EMIS</strong> SET,PRN,TEXT=“Lieferschein\r\n“<br />
OBC <br />
OBC <br />
OBC <br />
... ...<br />
<strong>EMIS</strong> SET,PRN,STATUS,MODE=“READY“<br />
Sening®<br />
Innovative Tank Truck Systems<br />
OBC <br />
After discharge the measuring system(s) access the printer for printing the original receipt. The<br />
printer access is requested from <strong>EMIS</strong>. For this reason the OBC must release the printer after<br />
printing the header by sending<br />
SET,PRN,STATUS,MODE=“READY“ wieder freigibt.<br />
10 - Check if all discharges are finished<br />
The measuring results can be found in the METER,ORDERS,RESULT(n) area. For a clear<br />
assignment the order corresponds to the presets, i.e. RESULT(0) contains the measuring<br />
results which correspond to PRESET(0), RESULT(1) corresponds to PRESET(1) etc.<br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,ORDERS,RESULT(0),Check<br />
OBC <br />
OBC REPORT,METER,ORDERS,RESULT(0),CHECK=““<br />
<strong>EMIS</strong> <br />
The result is not yet available. The procedure shown above must be performed for all expected<br />
results.<br />
Reasons: The discharge is not finished (in case of MultiFlow measuring systems, the actual<br />
mode can be determined by command REQUEST,METER(n),STATUS,MODE . If <strong>EMIS</strong> reports<br />
MODE=“BUSY“, the discharge is in progress) or the measuring system was not able to<br />
discharge the corresponding product (e.g. the system is not configured for this product).<br />
It must be considered that the job distribution can not be determined If several measuring<br />
systems are connected.<br />
� OBC must continue waiting for the result(s), interruption by the operator must be provided<br />
(if necessary)<br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,ORDERS,RESULT(0),Check<br />
OBC <br />
OBC REPORT,METER,ORDERS,RESULT(0),CHECK=“OK“<br />
<strong>EMIS</strong> <br />
The result is available. The procedure shown above must be performed for all expected results.<br />
� Proceed with the program.<br />
64 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E