EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Sening®<br />
Innovative Tank Truck Systems<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
Volume Measuring system display R 8<br />
PUnit<br />
Dimensional unit of the measuring system,<br />
e.g. „L“, „kg“<br />
R 3<br />
MeterID Measuring point identification R 15<br />
ReceiptID Receipt number, generated by counter R 10<br />
ModeID<br />
Discharge type of the measring system<br />
e.g. „VT“, „V15“ (or „MASS“)<br />
R 4<br />
AvTemp Mean discharge temperature e.g. „+25,2“ R 10<br />
TUnit e.g. „°C“<br />
Discharge date in keeping with measuring<br />
R 2<br />
Date system<br />
e.g. “01.12.2004“<br />
Discharge start time in keeping with<br />
R 8<br />
StartTime measuring system<br />
e.g. “16:17“<br />
R 5<br />
EndTime<br />
Discharge end time in keeping with<br />
measuring systems e.g. “16:32“<br />
R 5<br />
VT Uncompensated volume (in „L“) R 8<br />
VC Compensated volume (in „L“) R 8<br />
Mass Weight / mass (in „kg“) R 8<br />
Check<br />
“OK“ when RESULT data available<br />
““ when no RESULT data available<br />
R 2<br />
AvFlowrate Mean flow rate in L/Min R 5<br />
HoseSel Hose selection R 3<br />
TransMode Transfer mode R 2<br />
PriceFactor<br />
e.g. 100 (PUnit=“L“) then<br />
price per 100 litres<br />
R 5<br />
PRICE<br />
Price<br />
ExVat<br />
Price per (PUnit x PriceFactor)<br />
max. >> vvvvvv,nnn<br />
0= Preis incl. Vat / 1= excl.Vat<br />
Value –added tax 19.12 >><br />
R<br />
R<br />
10<br />
1<br />
Vat<br />
19.2%<br />
R 5<br />
ADDITIVE<br />
PCode PTB product code for additive R 3<br />
Volume<br />
Additive volume<br />
max. >> VVVVV,nn<br />
Dimensional unit for the<br />
R 8<br />
PUnit volume<br />
e.g. „ml“, „kg“<br />
R 3<br />
MixRatio<br />
Mixing ratio<br />
1500 >> 1:1500<br />
R 4<br />
PumpPos Position of the additive pump R 1<br />
RestVolume<br />
Remaining volume<br />
max. >> VVVVV,nn in PUnit<br />
R 8<br />
PriceFactor<br />
e.g. 1000 (PUnit=“mL“) then<br />
price per 1000 mLitre<br />
R 5<br />
Price<br />
Price per (PUnit x PriceFactor)<br />
max. >> vvvvvv,nnn<br />
R 10<br />
ExVat 0= Preis incl. Vat / 1= excl.Vat R 1<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 41<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Variablendefinition