Sening®<br />
Innovative Tank Truck Systems<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,SETUP<br />
OBC <br />
OBC REPORT,METER,SETUP,METERCOUNT=“0“;AUTOSCAN=“1“<br />
<strong>EMIS</strong> <br />
<strong>EMIS</strong> is scanning the CAN-bus for measuring systems during start-up ( AUTOSCAN=“1“ ) and<br />
did not find any systems ( METERCOUNT=“0“ ). Possible reason: measuring system(s) not<br />
switched on.<br />
� O OBC must perform error treatrment (e.g. display “please check measuring system(s)” ).<br />
3 - Check if measuring systems are able to communicate<br />
It is assumed that only one measuring system is connected to <strong>EMIS</strong> to make the further<br />
explanations in this chapter easier. If more than one systems is connected, all procedures<br />
described below have to be repeated for each measuring system.<br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />
OBC <br />
OBC REPORT,METER,STATUS(0),LASTERROR="000:Ready to receive next<br />
order";MODE="READY"<br />
<strong>EMIS</strong> <br />
The measuring system is connected, in operation and ready to receive the next order<br />
( MODE=“READY“ ).<br />
� Proceed with the program.<br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />
OBC <br />
OBC REPORT,METER,STATUS(1),LASTERROR="001:Locked with actual<br />
operation";MODE="BUSY"<br />
<strong>EMIS</strong> <br />
The measuring system is connected and in operation, but not able to receive the next order at<br />
present ( MODE=“BUSY“ ). This is caused e.g. by manual input at the measuring system<br />
(menu-mode) or a delivery in process.<br />
� Proceed with the program for the moment.<br />
Direction Telegram<br />
<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />
OBC <br />
<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />
OBC <br />
REPORT,ADMIN,STATUS,LASTERROR="5100:METER device not<br />
present";MODE="READY"<br />
<strong>EMIS</strong> <br />
The measuring systems does not answer the requests by <strong>EMIS</strong>.<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 59<br />