Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

Water sensor - WTR<br />

Identifier Identifier name Record<br />

configuration<br />

Field<br />

index <strong>Description</strong><br />

826 NODE_CONF 826,S,N,C,N,N 4 Compartment no.<br />

TDL Identifier 850 – new event information<br />

5 Sensor status<br />

Sening®<br />

Economic Tank Truck Systems<br />

<strong>EMIS</strong> "passes on" the data received from the QAS given a QAS,EVENT request to the OBC, i.e.<br />

no analysis or formating takes place. This means that unknown events from revised QAS versions<br />

can be easily handed on to the OBC. In contrast for the TDL output, the QAS data is changed into<br />

a new format in the <strong>EMIS</strong> – something which of course is only possible with known data. To output<br />

new and thus unknown data in the TDL format, the identifier is outputted with the possible 3<br />

parameters in 3 strings.<br />

Identifier Identifier name<br />

Record<br />

configuration<br />

850 NODE_CONF 850,S,N,C,<br />

C,C,C<br />

Example:<br />

Field<br />

index <strong>Description</strong><br />

4 TYP (see Chapter 4.2.1 / Page 30)<br />

5 VALUE1 (see Chapter 4.2.1)<br />

6 VALUE2 (see Chapter 4.2.1)<br />

Event / sensor TYPE VALUE1 VALUE2<br />

XXX example XXX CoNo e.g. 3 “AB“ = passiv<br />

“CD“ = active<br />

“EF“ = not connected<br />

“GH“ = short-circuit<br />

“IJ“ = invalid / unknown<br />

TDL unknown<br />

Event report line from REQUEST,QAS,EVENT-query:<br />

REPORT,QAS,EVENT,TYPE=“XXX“;VALUE1=“3“;VALUE2=“GH“;<br />

DATE=“11.10.2005“;TIME=“17:40“<br />

Event report line from REQUEST,TDL,L_FILE-query:<br />

REPORT,TDL,L_FILE=850,20051011174000,11,FAS,XXX,3,GH<br />

78 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E