Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

Sening®<br />

Innovative Tank Truck Systems<br />

� OBC must perform error treatment ( e.g. display “please check measuring system(s)” ).<br />

4 - Initialisation / clear all memories and devices<br />

Direction Telegram<br />

<strong>EMIS</strong> SET,METER,ORDERS,REINIT=“xxx“<br />

OBC <br />

Initialisation of measuring system(s) and <strong>EMIS</strong> memory acknowledged.<br />

� Proceed with the program.<br />

Direction Telegram<br />

<strong>EMIS</strong> SET,METER,ORDERS,REINIT=“xxx“<br />

OBC <br />

<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />

OBC <br />

OBC REPORT,ADMIN,STATUS,LASTERROR="5100:METER device not present";<br />

MODE="READY"<br />

<strong>EMIS</strong> <br />

The (or one of the) measuring system(s) does not answer the requests by <strong>EMIS</strong>. The error code<br />

will help to identify the system which caused the error (see chapter 4.8).<br />

� OBC must perform error treatment ( e.g. display “please check measuring system(s)” ).<br />

5 - Verify the success of the initialisation<br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />

OBC <br />

OBC REPORT,METER,STATUS(0),LASTERROR="000:Ready to receive next<br />

order";MODE="READY"<br />

<strong>EMIS</strong> <br />

The measuring system is connected, in operation and ready to receive the next order<br />

( MODE=“READY“ ), i.e. initialisation was sucessfull.<br />

� Proceed with the program.<br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />

OBC <br />

OBC REPORT,METER,STATUS(1),LASTERROR="001:Locked with actual<br />

operation";MODE="BUSY"<br />

<strong>EMIS</strong> <br />

The measuring system is connected and in operation, but not able to receive the next order at<br />

present ( MODE=“BUSY“ ). This is caused e.g. by a delivery in process.<br />

� OBC must perform error treatment ( e.g. display “please check measuring system(s)” ).<br />