Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

50nm<br />

Fault at connected device<br />

x: 0 = see LastError for the specified device<br />

1 = device not answering<br />

no others are defined<br />

n: device group (0:measuring system, 1:QAS)<br />

m: sequential number (starting with zero)<br />

Example: 5000 = fault at measuring system no. 1<br />

510m No answer from METER<br />

5110 No answer from QAS<br />

9998 Unknown value for the variable “Mode“<br />

9999 Unknown error<br />

Sening®<br />

Innovative Tank Truck Systems<br />

� If 2 errors occur one after another, the first will be overwritten. Therefore it is no longer<br />

available after read-out.<br />

� The error codes cannot be changed, but the texts are optional, and can vary between<br />

languages and the implementations of the application.<br />

5.2 METER, QAS, etc.<br />

The following errors are currently defined for the device structures (METER, QAS etc.):<br />

Code Meaning<br />

0xxx Device alarm, xxx = device specific alarm number<br />

Alarms represent faults that do not prevent continued execution of the program<br />

1xxx Device error, xxx = device specific error number<br />

52 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E