Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
50nm<br />
Fault at connected device<br />
x: 0 = see LastError for the specified device<br />
1 = device not answering<br />
no others are defined<br />
n: device group (0:measuring system, 1:QAS)<br />
m: sequential number (starting with zero)<br />
Example: 5000 = fault at measuring system no. 1<br />
510m No answer from METER<br />
5110 No answer from QAS<br />
9998 Unknown value for the variable “Mode“<br />
9999 Unknown error<br />
Sening®<br />
Innovative Tank Truck Systems<br />
� If 2 errors occur one after another, the first will be overwritten. Therefore it is no longer<br />
available after read-out.<br />
� The error codes cannot be changed, but the texts are optional, and can vary between<br />
languages and the implementations of the application.<br />
5.2 METER, QAS, etc.<br />
The following errors are currently defined for the device structures (METER, QAS etc.):<br />
Code Meaning<br />
0xxx Device alarm, xxx = device specific alarm number<br />
Alarms represent faults that do not prevent continued execution of the program<br />
1xxx Device error, xxx = device specific error number<br />
52 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E