29.11.2012 Views

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

EMIS Interface Description - Measurement Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Sening®<br />

Innovative Tank Truck Systems<br />

5 Error Messages<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

� All <strong>EMIS</strong> nodes contain the sub-nodes STATUS with the variables LastError (format:<br />

“ErrorCode:ErrorText”). The last occurring error of this device is stored here.<br />

� After read-out of these variables, the error is deleted.<br />

� After receipt of a , a read-out of ADMIN,STATUS,LastError should be performed.<br />

� Syntax or format errors occur most often and can be analysed here. In the case of an error<br />

code >= 5000 and < 6000 (format 5xnm), this means an error in conjunction with access to<br />

an external device. Inference to the relevant device can be drawn from n, inference to the<br />

running number from m.<br />

� With a second query of LastError of this device, the error can be determined. Error code and<br />

error message originate from the relevant device and are not documented here.<br />

5.1 ADMIN structure<br />

The following errors are currently defined for the ADMIN structure:<br />

Code Meaning<br />

0000 No error<br />

1000 Unknown command (OpCode) received<br />

1001 Unknown variable was selected<br />

1002 Telegram transmission failed (NAK received)<br />

1003<br />

Neither ACK nor NAK received for transmitted telegram (acknowledgement<br />

absent)<br />

1004 No reply received to REQUEST telegram<br />

1005 Reply to REQUEST telegram faulty or incomplete<br />

1006<br />

Index for variable outside permitted limits<br />

Example: Meter.Device(99)<br />

1007 No WaitOff received after WaitOn<br />

2000 Assigned value was truncated (character string too long)<br />

2001 Assigned value not possible (telegram format faulty)<br />

2002 Assigned value not possible (above/below permitted range)<br />

2003 Value assignment not possible (specified parameter invalid)<br />

3000 No write access to selected variable<br />

3001 Write access refused. The device is "Busy"<br />

4000 Internal error : ROM<br />

4001 Internal error : RAM<br />

4002 Internal error : EEPROM<br />

4003 Internal error : Clock<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 51<br />