Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

4.2.1 Events<br />

Sening®<br />

Innovative Tank Truck Systems<br />

All setup parameters and events are available via QAS,EVENT. Each entry contains a date and<br />

time specification, which however are not included in the following. Since <strong>EMIS</strong> only “hands over”<br />

the values from QAS, new values may be added in new QAS software versions which are not<br />

included here.<br />

Examples and special items for event queries are given in Chapter 3.6.4 / page 20.<br />

4.2.1.1 Setup Parameters<br />

In order to be able to interpret the correlation of individual events in an event query, it is often<br />

necessary to be acquainted with the basic settings of the QAS system.<br />

• For each QAS-EVENT query, the setup parameters are therefore transmitted first by default.<br />

• The time (QAS time) of the event query is output as the time stamp.<br />

• These are then followed by the actual events.<br />

• One setup parameter is transmitted per telegram.<br />

• Each setup parameter is specified in the form<br />

= = =.<br />

• The “SETn” value is optional and refers to the index number in NoMix / SPD Setup Index.<br />

SET01 System setup<br />

SET02 Components<br />

SET03 Network<br />

SET04 Tank truck<br />

SET05 Product<br />

SET06 Loading<br />

SET07 Discharge<br />

SET08 Sensors<br />

SET09 Events<br />

• Only the and the corresponding are necessary for an unambiguous<br />

evaluation.<br />

• The setup parameters are output by NoMix from version 1.43 and by MultiSeal from<br />

version 1.23.<br />

• The output is supported by <strong>EMIS</strong> from software revision 2.00.<br />

30 Rev. 2.00 / MB / jp / Juli 2008 MNF19002EUS / DOK-411E