EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Sening®<br />
Innovative Tank Truck Systems<br />
4 Variablendefinition<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
The use of upper and lower case letters is irrelevant to the interpretation (syntax), and is used<br />
simply to clarify the hierarchy.<br />
4.1 ADMIN – (<strong>EMIS</strong>)<br />
ADMIN-Variables Remarks Access Length<br />
Serial e.g. “18DL0001” R 10<br />
Name e.g. “<strong>EMIS</strong>2“ R 15<br />
DEVICE HWVersion e.g. “02.00<strong>EMIS</strong>2“ R 10<br />
SWVersion e.g. “03.12<strong>EMIS</strong>2“ R 10<br />
Node CAN-bus node no.of the device typisch “21“ R 2<br />
LastError See table in Chapter 5 / page 51 R 50<br />
STATUS<br />
Mode<br />
e.g. “Ready”: Ready for operation<br />
(see chap. 3.5 / page 16 )<br />
R 10<br />
Reset<br />
Setting (SET) this variable releases a<br />
software RESET<br />
W 15<br />
VEHICLE Name e.g. license plate number “HH AB 123“ R/W 15<br />
Date Date e.g. “01.01.2005“ R/W 10<br />
Time Time e.g. “01:01:10“<br />
(Daylight Saving Time)<br />
“0” no automatic summer winter time<br />
R/W 8<br />
CLOCK AutoDST<br />
daylight saving<br />
“1” automatic summer winter time daylight<br />
saving on last Sunday in March and on<br />
last Sunday in October respectively<br />
R/W 1<br />
CurrentDST<br />
“0” current time is wintertime<br />
“1” current time is summertime<br />
R 1<br />
Version „2.10“, corresponds to available specification<br />
Setting (SET) this variable releases an<br />
R 15<br />
Ping<br />
autom. REPORT telegram. It serves the<br />
connection for the examination.<br />
W 15<br />
Meters<br />
Number of max. supported meters:<br />
typical “3“<br />
R 2<br />
PROTOCOL<br />
OPTION<br />
QAS<br />
OBC<br />
PRN<br />
Number of max. supported QAS:<br />
typical “1“<br />
Number of max. supported QBCs:<br />
typical “1“<br />
Number of max. supported Printer:<br />
typical “1“<br />
R<br />
R<br />
R<br />
2<br />
2<br />
2<br />
COM<br />
Number of max. supported serial interfaces:<br />
typical "2"<br />
R 2<br />
GPS<br />
Number of max. supported GPS module:<br />
typical “1“<br />
R 2<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 25<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Variablendefinition