Sening®<br />

Innovative Tank Truck Systems<br />

4.2.1.3 Event Table<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

� See below for information on the foot notes and abbreviations used in the table.<br />

Event / sensor TYPE VALUE1 VALUE2<br />

API coupling<br />

(sensor status)<br />

AST CoNo<br />

TDL 42,S,V1,2,(1) (2) >> V2[..]<br />

ACCU-Load<br />

Communication<br />

ALC<br />

TDL 825,S,NoID,FAS,V1 4)<br />

Footvalve<br />

(sensor status)<br />

BST CoNo<br />

TDL 42,S,V1,1,(1) (2) >> V2[..]<br />

Footvalve left = standard<br />

(solenoid valve)<br />

BVL CoNo<br />

TDL 43,S,V1,1,(1) (2) >> V2[..]<br />

Footvalve right<br />

(solenoid valve)<br />

BVR CoNo<br />

Connection to ACCU-<br />

Load<br />

“0“ = interrupted<br />

“1“ = connected<br />

TDL 43,S,V1,1,(1) (2) >> V2[..],2<br />

Cabinet flap<br />

(sensor status)<br />

CAB<br />

Instrumentation cabinet<br />

”L” = left<br />

“R“ = right<br />

TDL 42,S, ,7,(1) (2) >> V2[..],(1) (2) >> V1[..]<br />

Compartment status CFS CoNo<br />

TDL 40,S,V1, ,(0) (1) (1) () (2) ()>> V2[..]<br />

Overfill prevention<br />

(sensor status)<br />

COF<br />

TDL 42,S,V1,17,1<br />

Seal status CST CoNo<br />

CoNo. for which the<br />

overfill protection has<br />

triggered<br />

“L“ = locked<br />

“U“ = unlocked<br />

“L“ = closed (pressure low)<br />

“H“ = open (pressure high)<br />

“0“ = closed<br />

“1“ = open<br />

“0“ = closed<br />

“1“ = open<br />

Action<br />

“0“ = closed<br />

“1“ = open<br />

“0“ = empty<br />

“1“ = not empty<br />

“2“ = remaining quantity (not<br />

empty)<br />

“3“ = unknown<br />

“4“ = Full<br />

“5“ = Fault<br />

“E“ = empty (not sealed)<br />

“R“ = remaining quantity (not<br />

empty)<br />

“S“ = sealed<br />

“L“ = second sealing when loading<br />

“D“ = second sealing when<br />

discharging<br />

“?“ = unknown<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 33<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9<br />

A<br />

Variablendefinition