EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
EMIS Interface Description - Measurement Solutions
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Sening®<br />
Innovative Tank Truck Systems<br />
4.2.1.3 Event Table<br />
Specification<br />
Euro <strong>Interface</strong> <strong>EMIS</strong><br />
<strong>Interface</strong> <strong>Description</strong><br />
� See below for information on the foot notes and abbreviations used in the table.<br />
Event / sensor TYPE VALUE1 VALUE2<br />
API coupling<br />
(sensor status)<br />
AST CoNo<br />
TDL 42,S,V1,2,(1) (2) >> V2[..]<br />
ACCU-Load<br />
Communication<br />
ALC<br />
TDL 825,S,NoID,FAS,V1 4)<br />
Footvalve<br />
(sensor status)<br />
BST CoNo<br />
TDL 42,S,V1,1,(1) (2) >> V2[..]<br />
Footvalve left = standard<br />
(solenoid valve)<br />
BVL CoNo<br />
TDL 43,S,V1,1,(1) (2) >> V2[..]<br />
Footvalve right<br />
(solenoid valve)<br />
BVR CoNo<br />
Connection to ACCU-<br />
Load<br />
“0“ = interrupted<br />
“1“ = connected<br />
TDL 43,S,V1,1,(1) (2) >> V2[..],2<br />
Cabinet flap<br />
(sensor status)<br />
CAB<br />
Instrumentation cabinet<br />
”L” = left<br />
“R“ = right<br />
TDL 42,S, ,7,(1) (2) >> V2[..],(1) (2) >> V1[..]<br />
Compartment status CFS CoNo<br />
TDL 40,S,V1, ,(0) (1) (1) () (2) ()>> V2[..]<br />
Overfill prevention<br />
(sensor status)<br />
COF<br />
TDL 42,S,V1,17,1<br />
Seal status CST CoNo<br />
CoNo. for which the<br />
overfill protection has<br />
triggered<br />
“L“ = locked<br />
“U“ = unlocked<br />
“L“ = closed (pressure low)<br />
“H“ = open (pressure high)<br />
“0“ = closed<br />
“1“ = open<br />
“0“ = closed<br />
“1“ = open<br />
Action<br />
“0“ = closed<br />
“1“ = open<br />
“0“ = empty<br />
“1“ = not empty<br />
“2“ = remaining quantity (not<br />
empty)<br />
“3“ = unknown<br />
“4“ = Full<br />
“5“ = Fault<br />
“E“ = empty (not sealed)<br />
“R“ = remaining quantity (not<br />
empty)<br />
“S“ = sealed<br />
“L“ = second sealing when loading<br />
“D“ = second sealing when<br />
discharging<br />
“?“ = unknown<br />
MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 33<br />
1<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
9<br />
A<br />
Variablendefinition