Sening®<br />

Innovative Tank Truck Systems<br />

Specification<br />

Euro <strong>Interface</strong> <strong>EMIS</strong><br />

<strong>Interface</strong> <strong>Description</strong><br />

Direction Telegram<br />

<strong>EMIS</strong> REQUEST,METER,STATUS(0)<br />

OBC <br />

<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />

OBC <br />

REPORT,ADMIN,STATUS,LASTERROR="5100:METER device not present";<br />

MODE="READY"<br />

<strong>EMIS</strong> <br />

The measuring systems does not answer the requests by <strong>EMIS</strong>.<br />

� OBC must perform error treatment ( e.g. display “please check measuring system(s)” ).<br />

6 - Transmission of presets to <strong>EMIS</strong><br />

Direction Telegram<br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(0),PCODE=“1“;VOLUME=“10000“;PUNIT=“L“<br />

OBC <br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(1),PCODE=“3“<br />

OBC <br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(1),VOLUME=“2000“<br />

OBC <br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(1),PUNIT=“L“<br />

OBC <br />

Up to 10 presets (index 0..9) may be transmitted for the present version of <strong>EMIS</strong>. Both presets<br />

in the example above have been acknowledged by <strong>EMIS</strong>. The example shows two alternatives:<br />

Transmission of all preset-information with one set command (preferred variant) or transmission<br />

of the preset data with separate telegrams.<br />

� Proceed with the program.<br />

Direction Telegram<br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(0),PCODE=“1“<br />

OBC <br />

<strong>EMIS</strong> SET,METER,ORDERS,PRESET(1),PCODE=“3“<br />

OBC <br />

<strong>EMIS</strong> REQUEST,ADMIN,STATUS<br />

OBC <br />

REPORT,ADMIN,STATUS,LASTERROR="1006:Index out of range";<br />

MODE="READY"<br />

<strong>EMIS</strong> <br />

Each preset has to be transmitted completely in the correct order. If one preset is not<br />

completed, <strong>EMIS</strong> will reject the transmission of further presets.<br />

MNF19002EUS / DOK-411E Rev. 2.00 / MB / jp / Juli 2008 61<br />